background image

                                                            

SmartLock

®

 UltraLite Plus 

                       

Page 15 of 16

 

                                                                  

Installation Manual

                                      

Oct 2013 • Rev. 1.6

 

Compliance statements for : 

 

 

Federal Communications Commission (FCC) 
Statement 

Note:

 This equipment has been tested and found to comply with the limits for a class B digital 

devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, uses, 
and can radiate radio frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If this equipment does cause 
harmful interference to radio or television reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:  

 

Reorient or relocate the receiving antenna.  

 

Increase the separation between the equipment and receiver.  

 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected.  

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) this device may not cause harmful interferences, and (2) this device must accept 
any interferences received, including interference that may cause undesired operation.  

Complies To:  

 

 

 

Summary of Contents for SmartLock UltraLite Plus

Page 1: ...SmartLock UltraLite Plus INSTALLATION MANUAL October 2015...

Page 2: ...K RELAY WIRING 10 TROUBLESHOOTING 14 SMARTLOCK ULTRALITE PLUS COMPLIANCE STATEMENT 15 Copyright 2012 2015 Cansec Systems Ltd All rights reserved Connector Installation Note 6 Wiegand Reader 7 iButton...

Page 3: ...uest to exit button and a door contact If a door contact input is connected the controller will automatically relock the door once it re closes In addition an audible alert can be generated on the rea...

Page 4: ...m 500 max iButton readers 6 conductors 22 AWG shielded or unshielded cable 15 m 50 max Dimensions UltraLite Plus controller 114 3 mm h x 44 5 mm w x 25 4 mm d 4 5 h x 1 75 w x 1 d Operating Temperatu...

Page 5: ...r contact input must be bypassed if not used To bypass connect a jumper wire between the door contact input and Ground 3 If the cable feed hole on the controller back box is too small drill a larger h...

Page 6: ...nstallation Manual Oct 2013 Rev 1 6 Wiring CONNECTOR INSTALLATION NOTE IMPORTANT Wires face into the center of the PCB for installation into housing CONNECT WIRES ONTO THE PLUGGABLE CONNECTORS IN THIS...

Page 7: ...Manual Oct 2013 Rev 1 6 WIEGAND READER IMPORTANT Before applying power to the controller verify that the reader is connected correctly as per the manufacturer s specifications 6 CONDUCTOR 20 AWG NON...

Page 8: ...SmartLock UltraLite Plus Page 8 of 16 Installation Manual Oct 2013 Rev 1 6 IBUTTON READER 6 CONDUCTOR 22 AWG TWISTED OR NON TWISTED PAIR SHIELDED CABLE MAX DISTANCE IS 50 FT...

Page 9: ...for forced entry and door held open annunciation The lock relay is deactivated when the door closes before the unlock time ends 3 If door contact is not used you must connect a jumper wire between the...

Page 10: ...te Plus Page 10 of 16 Installation Manual Oct 2013 Rev 1 6 Lock Relay Wiring DC ELECTRIC STRIKES UP TO 250MA NOTE Use a 1N400x series diode at the lock device as shown to prevent back EMF from damagin...

Page 11: ...Lite Plus Page 11 of 16 Installation Manual Oct 2013 Rev 1 6 DC ELECTRIC STRIKES MORE THAN 250MA NOTE Place a 1N400x series diode at the external relay coil as shown to prevent back EMF from damaging...

Page 12: ...ck UltraLite Plus Page 12 of 16 Installation Manual Oct 2013 Rev 1 6 AC ELECTRIC STRIKES NOTE Place a 1N400x series diode at the external relay coil as shown to prevent back EMF from damaging the cont...

Page 13: ...maging the controller IMPORTANT In some jurisdictions the use of a UL approved power supply and connection to the fire alarm system for emergency release may be required Installers should contact the...

Page 14: ...s OFF Continuous Beeps Access Granted 130 ms ON Single Beep Access Denied first beep 130 ms ON then 20 ms OFF second beep 130 ms ON then OFF Two Beeps Door Held Open Continuous tone Continuous Beep Pr...

Page 15: ...e is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning th...

Page 16: ...rique de la classe B respecte toutes les exigences du R glement sur le mat riel brouilleur du Canada Complies To European Community Compliance Statement This product has been tested and found to comp...