STEP 4 – CLEAR PANEL MEMORY
1.
Referring to
Options DIP Switch S1
(
see Figure 2:
D
),
slide
switch 3 (OPT3)
to the right (
ON
).
2.
Press and release the
Reset button
(see Figure 2:
C
)
.
3.
“Clearing Panel Memory” is indicated by the rapid flashing of the H1000
onboard Reader LEDs labeled
RLED1
(
see Figure 2:
E
)
and
RLED3
(
see
Figure 2:
F
)
for approximately 20 seconds. Note: Only the appropriate LEDs
that are ‘ON’ will be flashing during this process.
4.
The H1000
onboard beeper
(
see Figure 2:
H
)
begins to beep continuously to
indicate that the panel memory is cleared.
5.
Slide
switch 3 (OPT3)
(
see Figure 2:
D
)
back to the left (
OFF
).
6.
Press and release the
Reset button
(see Figure 2:
C
).
H1000 Panel database is
now cleared to virgin state and
ready for operation.
Figure 2: H1000 Version 1.1 Operational Parts Location