CanLan 

Page 13 of 31 

 

Installation Manual 

August 2014 • Rev. 1.2 

8.

 

If LED B is off, first power the CanLan off and on again, and then make 
your selection (as above). 

9.

 

Press 

OK

10.

 

 Once a connection is established, the configuration software will retrieve 
the current data from the CanLan. 

11.

 

 The red connection icon at the bottom of the configuration software 
window will change to green and the message 

Unit Online

 will be 

displayed. LED B will stay on until 

Quit 

is pressed. 

 
 
 
 
 
 
 
 
 
 
 
 

Troubleshooting Tips

 

If a connection cannot be established, the connection icon will remain red 
and the status line will report Unit Offline. 

 

Verify the CanLan Connection 

If you are using a network connection, go to 

Start >Run

 and type 

cmd

 

and click 

OK

 to launch the Windows

®

 command prompt. Type 

ping 

10.0.0.100

 and then hit the 

Enter

 key on your keyboard. If there is no 

reply, double-check the cable connection and/or IP settings.

 

 

Try a Serial Connection 

If successive attempts to establish a network connection are unsuccessful, 
try using a serial connection instead. 

 

For more troubleshooting tips, see the 

Troubleshooting a Connection

 section 

at the end of this manual. 

 

Summary of Contents for Canlan

Page 1: ...Canlan INSTALLATION MANUAL August 2014...

Page 2: ......

Page 3: ...Network Connection 9 Making a Connection 11 Setup and Configuration 14 Address Configuration 14 Operational Mode 15 Remote Diagnostics 16 Serial Interface 17 Saving the Settings 17 Commands 18 Connec...

Page 4: ...16 CP40 or 30 Smartlock control panels On Maestro systems network traffic only occurs when events or commands need to be relayed between the host and the control panels Bandwidth is conserved through...

Page 5: ...face and the status LEDs A RS232 Port Activity LED flashes when there is activity on the RS232 interface B RS485 Port Activity LED flashes when there is activity on the RS485 interface C Link Activity...

Page 6: ...connector on the back of the Canlan NOTE a power outage will result in a 20 30 loss of connectivity to the device 12 VDC Battery Backup recommended The Canlan can be wired via the RS485 header connect...

Page 7: ...s a 3 wire interface with the following pin outs 1 Not Used 2 RX 3 TX 4 Not Used 5 Gnd 6 Not Used 7 Not Used 8 Not Used RS485 Header Connector The RS485 header connector has the following pin outs 1 R...

Page 8: ...anual August 2014 Rev 1 2 Installing the Canlan Software 1 Insert the mini CD into your computer s CD drive 2 Go to My Computer and double click your computer s CD drive 3 Double click Setup exe 4 Fol...

Page 9: ...onnection SERIAL CONNECTION 1 Connect the CanLan to the PC using the DB9 data cable provided 2 Continue to the Making a Connection section on page11 NETWORK CONNECTION Before connecting the CanLan and...

Page 10: ...rotocol TCP IP from the list and press the Properties button 4 Write down your current settings 5 Select Use the following IP address and enter IP address 10 0 0 1 Subnet Mask 255 255 255 0 Default Ga...

Page 11: ...n software to the CanLan during the 20 second configuration period If the 20 second configuration period expires before you make a connection simply power the CanLan off and then power it back on agai...

Page 12: ...rial Port and choose the appropriate COM Port from the drop down menu 7 If you are using a network connection choose Connect via Network and enter the CanLan s default IP address 10 0 0 100 The COM Po...

Page 13: ...Troubleshooting Tips If a connection cannot be established the connection icon will remain red and the status line will report Unit Offline Verify the CanLan Connection If you are using a network con...

Page 14: ...iagnostics and Serial Interface Each section reflects a group of settings that will be stored in the Canlan s flash memory ADDRESS CONFIGURATION The Address Configuration section defines the static IP...

Page 15: ...he idle auto disconnect inactivity timer drops any active host connection after a specified interval in minutes during which no data is transmitted or received This option helps prevent against a hung...

Page 16: ...ore details The Canlan implements a set of diagnostic commands which can be issued from the Advanced Diagnostic software tool In addition it continues to support execution tracing at selectable detail...

Page 17: ...not the cable type used to configure the Canlan RS485 Interface If the Canlan will be connected to the control panels using an RS485 connector choose RS485 Interface Setup When an operational mode is...

Page 18: ...he Canlan replacing the existing settings Save downloads the current settings to the Canlan and writes them to flash memory Version displays the Canlan firmware revision information Default sets all p...

Page 19: ...nlan to a Control Panel The Canlan may be connected to up to 16 CP40 access control panels or up to 30 SmartLock access control panels Refer to the SmartLock Pro Installation Manual or the CP40 Instal...

Page 20: ...lation and Configuration guide for details NOTES ADDRESS 1 SHOWN Dipswitch 1 is OFF CANLAN TCP IP CONTROLLER SMARTLOCK CONTROLLER 1 ON OFF ON 8 1 5V 12V ADDRESS SWITCH B A GND B A GND SHIELD GND 12 VD...

Page 21: ...485 5 8 7 GND 12 VDC NOTE It is highly recommended that the Canlan be powered by 12 VDC output from a Cansec access control panel with battery backup This will prevent connectivity loss during a power...

Page 22: ...a connection to the Canlan from the appropriate host software The following sections give a brief overview of how to define a new Canlan using either Maestro software Smartlock Pro software MAESTRO C...

Page 23: ...estart the software and view the current connection status of the trunk by choosing VIEW COMMUNICATIONS from the menu The communications status window will be displayed Select the trunk line from the...

Page 24: ...t be entered as set on the CP40 address dip switches In the next entry enter the number of the new virtual trunk we defined in the Network Trunk Definitions dialog Enter one or more card readers each...

Page 25: ...on Problems If there is a communication problem between the Canlan and the access control panel it will be reflected in the Timeouts column for each respective control panel The Timeouts column counts...

Page 26: ...inition dialog at right is displayed Enter the address of the new control panel that was connected to the Canlan and give it a name Select the Connection tab Direct Serial Connection choose this optio...

Page 27: ...EW STATISTICS from the menu bar The communication statistics window will appear displaying statistics about connected control panels as well as information regarding the current Canlan connection stat...

Page 28: ...within a second or two after the connection is initiated If the status remains in the Connecting state then there maybe an issue with that Canlan configuration or socket connectivity issues through r...

Page 29: ...rs code and are fixed The remaining 3 bytes are unique for each device produced by that manufacturer The manufacture s code for the Canlan is 00 90 C2 with the remain 3 bytes differing for each unit I...

Page 30: ...allation Manual August 2014 Rev 1 2 If the unit has not been installed yet the last three bytes 6 characters are stenciled on the CPU module as shown below The MAC address is the same as the previous...

Page 31: ...tware including IP address is correct and then press SAVE Power off the Canlan wait a few seconds and power it back on again LED B should stop flashing while in the 20 second configuration mode Rechec...