6. Align sensor to sensor target. Adjust the sensor target to a minimum gap of 0.03" and a
maximum gap of 0.048". Do not adjust the sensor. See Figure 5.
Figure 5: Sensor Alignment
7. Attach and tighten sensor cable to the back of the sensor as shown in Figure 6.
8. Install the unlocking safety clip (P/N: E19187-CLIP) around the sensor and sensor cable.
Figure 6: Sensor Cable Installation
9. Route the new sensor cable through the top drive following the same route as the old sensor
cable to the PLC J-box.
10. Disconnect the old sensor cable from the J-box and remove it from the top drive.
.03 [1] MIN GAP
.048 [1.2] MAX GAP
Sensor
Sensor target
Sensor cable
Sensor