6. Align sensor to sensor target. Adjust the sensor target to a minimum gap of 0.03" and a 

maximum gap of 0.048". Do not adjust the sensor. See Figure 5.

Figure 5: Sensor Alignment

7. Attach and tighten sensor cable to the back of the sensor as shown in Figure 6.

8. Install the unlocking safety clip (P/N: E19187-CLIP) around the sensor and sensor cable.

Figure 6: Sensor Cable Installation

9. Route the new sensor cable through the top drive following the same route as the old sensor 

cable to the PLC J-box.

10. Disconnect the old sensor cable from the J-box and remove it from the top drive.