2. Entrance sensor lever spring failure
Action:
Reset the spring correctly. Replace the spring if deformed or damaged.
3. Entrance sensor failure
Action:
Conduct the sensor check mode described on Page 4-7 and see if the sensor is nor-
mal. If it is not normal, replace it.
4. Face-up deflector failure
Action:
Check the deflector, and replace it if it is worn, fractured, dented, or scarred.
5. Worn/deformed/dirty feed roller 1.
Action:
Clean the roller if dirty. Replace the roller if worn or deformed.
6. Worn/deformed/dirty reversing roller
Action:
Clean the roller if dirty. Replace the roller if worn or deformed.
7. Damaged gears
Action:
Replace any damaged gear.
8. Poor contact in reversing roller drive solenoid drive signal line connector.
Action:
Reconnect the connector J14 on the staple stacker driver PCB.
9. Reversing roller drive solenoid failure
Action:
Disconnect the connector J14 on the staple stacker driver PCB. Measure the resis-
tance between the connector J14-1 and J14-2 on the solenoid side. If it is not about
125
Ω
, replace the reversing roller drive solenoid.
10. Staple stacker driver PCB failure
Action:
Replace it.
4 - 10
CHAPTER 4
Summary of Contents for STAPLER STACKER SS-72
Page 8: ......
Page 24: ......
Page 26: ......
Page 58: ......
Page 67: ...IV MAIN PARTS A Locations Stapler Figure 3 4 1 3 9 CHAPTER 3 ...
Page 92: ......
Page 94: ......
Page 101: ...This page intentionally left blank 4 7 CHAPTER 4 ...
Page 116: ...This page intentionally left blank 4 22 CHAPTER 4 ...
Page 121: ...APPENDIX I GENERAL CIRCUIT DIAGRAM A 1 II LIST OF SIGNALS A 3 ...
Page 122: ......
Page 124: ......
Page 128: ......