CHAPTER 5 TROUBLESHOOTING
5-10
COPYRIGHT © 1998 CANON INC.
CANON STAPLER SOTRER-L1 MS-C1 REV.0 NOV. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
4. Adjusting the Position of the Guide Stopper (Stapler sorter only)
If you have replaced the stapler swing unit or reassembled it, you must adjust the position of
the guide stopper, as the paper retaining arm position is likely to have been displaced.
1) Making Adjustments
Check to make sure that the paper retaining arm [2] and the guide stopper [3] are in light
contact with the arm bracket [4] when the stapler unit [1] is at the home position. If not, loosen the
screws [5] and [6] on the guide stopper, and keep the guide stopper [3] in contact with the paper
retaining arm [2], and tighten the screw [6]. Then, slide the stapler unit [1], and fix it in place by
tightening the screw [5].
[4]
[2]
[1]
[3]
[6]
[5]
Figure 5-113