CHAPTER 2 USING THE MACHINE
COPYRIGHT © 2002 CANON INC.
2000 2000 2000 2000
CANON SmartBase PC1210D/1230D/1270D REV. 1 MAR. 2002
2-36
Memo
The following error codes are associated with the line condition at time of re-
ception:
##107, ##114, ##201
Be sure to change bit 4 before changing this bit; resort to this bit only if an
error still occurs.
When set to ‘1’, only high-speed (image) signals will be received after the
transmission of the CFR signal.
[Bit 4]
Use it to select the length of time during which low-speed signals are ignored after trans-
mission of the CFR signal.
Select ‘1500 msec’ if reception of image signals is not good because of a poor line condi-
tion.
[Bit 7]
Use it to specify whether or not to send the CED signal at time of manual reception.
Set it to ‘transmit’ if the other party does not start transmission when manual reception is
initiated.