background image

ENG-7

2.  Setting the Focus Mode 3. Zooming

To zoom, turn the Lens’ zoom ring.

 

z

 Be sure to finish zooming before focusing. 

Zooming after focusing can affect the focus.

 

z

 Blurring may temporarily occur if the zoom ring is 

quickly turned.

Focus mode switch

Focusing ring

To shoot in autofocus (AF) mode, set the focus 

mode switch to AF.

To use only manual focusing (MF), set the focus 

mode switch to MF, and focus by turning the 

focusing ring.

 

z

 Quickly turning the focusing ring may result in 

delayed focus.

 

z

The lens’ focusing ring is electronic.

 

z

 Manual focus is possible even when the focus 

mode switch is set to AF. (Full-time manual focus) 

However, the camera settings need to be changed. 

Please refer to the camera's instructions for details.

Summary of Contents for RF 24-70mm F2.8 L IS USM

Page 1: ...ENG Instructions ...

Page 2: ...r Ultrasonic Motor Camera Firmware Please use the latest version of firmware with the camera in use For details on whether the firmware is the latest version or not and for details on updating the firmware please check the Canon website Conventions used in these instructions Warning to prevent lens or camera malfunction or damage Supplementary notes on using the lens and taking pictures ...

Page 3: ...light sources through a lens This may result in loss of sight z z Do not leave a lens in the sun without the lens cap attached The lens may concentrate entering sunlight and cause a malfunction or fire Caution Details pertaining to risks that may result in injury or damage to other objects z z Do not leave the product in places exposed to extremely high or low temperatures The product may cause bu...

Page 4: ...ation may develop on the lens surface and internal parts To prevent condensation in this case first put the lens into an airtight plastic bag before taking it from a cold to warm environment Then take out the lens after it has warmed gradually Do the same when taking the lens from a warm environment into a cold one z z Please also read any lens related handling precautions listed in your camera s ...

Page 5: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio ...

Page 6: ...ing thread 13 Control ring 9 Focusing ring 7 Image stabilizer switch 10 Lens mount index 6 Zoom position index 7 Zoom ring lock lever 8 Rubber ring 6 Contacts 6 Lens mount 6 z z For detailed information reference page numbers are provided in parentheses Nomenclature ...

Page 7: ...ens place the lens with the rear end up and attach the dust cap to prevent the lens surface and contacts from getting scratched Make sure the lens and dust cap mount indexes are aligned when attaching the dust cap z z Contacts that are scratched soiled or have fingerprints on them may result in faulty connections or corrosion which may lead to malfunctions If the contacts get soiled clean them wit...

Page 8: ...o shoot in autofocus AF mode set the focus mode switch to AF To use only manual focusing MF set the focus mode switch to MF and focus by turning the focusing ring z z Quickly turning the focusing ring may result in delayed focus z z The lens focusing ring is electronic z z Manual focus is possible even when the focus mode switch is set to AF Full time manual focus However the camera settings need ...

Page 9: ... because it prevents the lens from extending 2 Slide the zoom ring lock lever in the direction indicated by the arrow z z To release the zoom ring slide the zoom ring lock lever in the direction opposite to the arrow 1 Turn the zoom ring to the widest position 24 mm z z The zoom ring cannot be fixed in place at any position other than the widest position ...

Page 10: ...ontrol ring allows you to have a sense of how much it is being turned Please refer to the camera s instructions for details on how to use the control ring z z There are cases in which the sound of control ring operations may be recorded when shooting movies z z The clicking sensation of the control ring can be removed by the Canon Service Center chargeable 5 Control Ring ...

Page 11: ...ation z z The Image Stabilizer operates for about two seconds after turning off the camera Do not detach the lens during that time This may cause the lens to malfunction z z When using a tripod it is recommended that you set the image stabilizer switch to OFF z z Even with a monopod the Image Stabilizer will be as effective as during hand held shooting However depending on the shooting conditions ...

Page 12: ...izer z z In semi darkened areas such as indoors or outdoors at night z z In locations where the flash cannot be used such as art museums and theater stages z z In situations where your footing is uncertain z z In situations where fast shutter speed settings cannot be used z z Panning shots of vehicles trains etc ...

Page 13: ...Button Detaching the Hood Keep your finger pressed down on the button located on the side of the hood and then turn the hood in the direction of the arrow until the attachment position mark on the hood is aligned with the red dot on the front of the lens to detach it The hood can be reverse mounted on the lens for storage z z If the hood is not attached properly vignetting darkening of the perimet...

Page 14: ...tach filters to the filter mounting thread on the front of the lens z z Only one filter may be attached z z If you need a polarizing filter use the Canon Circular Polarizing Filter PL C B z z Detach the hood when adjusting the polarizing filter ...

Page 15: ...0 mm 0 38 m 1 25 ft Filter Diameter 82 mm Max Diameter and Length Approx 88 5 x 125 7 mm 3 48 x 4 95 in Weight Approx 900 g 31 7 oz Hood EW 88E Lens Cap E 82II Case LP1222 z z The lens length is measured from the lens mount surface to the front end of the lens Add 24 0 mm 0 94 in when including the lens cap and dust cap z z The maximum diameter length and weight listed are for the lens itself only...

Page 16: ...CT1 D100 B 0619Ni CANON INC 2019 ...

Reviews: