NOTE:
Service Mode
• ON/OFF of POD Deck Lite air assist
(Lv.2) COPIER > OPTION > FEED-SW > DK1-AIR
• Deck Air Float Fan airflow amnt: dwstm
(Lv.2) COPIER > OPTION > FEED-SW > DK1-ALVD
• Deck Air Float Fan airflow amnt: upstream
(Lv.2) COPIER > OPTION > FEED-SW > DK1-ALVU
To adjust the airflow amount of the Air Floatation Fan of the POD Deck Lite.
When making an adjustment, be sure to adjust the setting of DK1-ALVD and DK1- ALVU at the same time.
<Setting value >
-10 to 10 [default: 0]
<Use case >
When double-feed occurs
<Caution >
If the value is large, uneven transfer may occur. If the value is small, double feed may occur.
■ Swing Operation
This equipment combines the air blowing operation against paper with the swing operation of the shutter to improve separation
of paper. The swing motor (M4) drives the shutter to move up and down.
The direction of air blow against paper changes up or down repeatedly, vibrating the paper for easier separation.
The swing HP sensor (SR16) detects a failure of up and down operation of the shutter and the home position of the shutter.
Paper type: Different depending on the host machine.
“Air Assist Control” on page 21
Swing motor(M4)
Swing HP sensor(SR16)
Shutter
Cassette Heater Control (Option)
To facilitate separation of paper in a high humidity environment, a cassette heater unit is available optionally. When the cassette
heater (H1) is powered, the temperature in the deck becomes suitable and thereby the humidity lowers, facilitating separation of
paper. When the cassette heater switch mounted at the rear of this equipment is set at OFF, the cassette heater (H1) is not
powered. When the cassette heater switch is set to ON, the cassette heater is continuously powered.
2. Technology
22
Summary of Contents for POD Deck Lite-C1
Page 1: ...Revision 2 0 POD Deck Lite C1 Service Manual ...
Page 10: ...Product Overview 1 Features 5 Specifications 6 Names of Parts 7 Option Construction 10 ...
Page 17: ...Technology 2 Basic Configuration 12 Controls 15 Upgrading 26 ...
Page 33: ...Periodical Service 3 List of Work for Scheduled Servicing 28 ...
Page 37: ...6 Remove the base stay unit 3 Screws 3x 4 Disassembly Assembly 31 ...
Page 52: ... Procedure 1 Remove the Upper Cover 5 Screws 5x 4 Disassembly Assembly 46 ...
Page 69: ...5 Remove the Air Heater from rear of the Compartment 2 Screws 2x 4 Disassembly Assembly 63 ...
Page 72: ...2 Remove the Deck Pickup Release Solenoid 2 Screws 2x 4 Disassembly Assembly 66 ...
Page 93: ...Adjustment 5 Adjustment 88 Actions when Replacing the Parts 90 Other Adjustment 96 ...
Page 150: ...APPENDICES Service Tools 145 General Circuit Diagram 146 ...