8
Non-Contact Displacement Sensor User’s Manual Rev 1.00
③
Power connector
Connect the power cable (AM4-0085). 12 to 24V DC power input is supported.
④
Status indicator
Turns on or blinks while the main unit is operating.
Condition
Power
Status
Powered on
On
Off
A warning occurs
On
Blinking
An error occurs
On
On
⑤
Mounting screw holes
Mount the main unit with four M4 screws. The board thickness of the screw hole parts is 6 mm. Select the screw
length depending on the location where the main unit is fixed. To prevent screws from loosening by vibration, it is
recommended that you take screw locking action.
(For how to fix the main unit, see section 1-4-1.)
⑥
Optical window
Irradiates LED light to measure the length, and receives light diffuse-reflected by the target measurement object.
Protected by the cover glass.
⑦
Length measurement direction
The direction of the arrow shown in the figure indicates the length measurement direction (work moving direction).