PC-D320/PC-D340/FAX-L400 Chapter 4: Maintenance and Service
4-19
No.
Tx or Rx
Definition
##0290
[TX
]
After transmitting MPS, a signal other than PIN, PIP,MCF,
RTP, or RTN was received
##0295
[TX
]
For the auto alarm notification function, the other party does not
have an NTT remote maintenance function
##0670
[TX
]
In V.8 late start, the V.8 ability was detected in DIS from the
other party and, in response, CI was transmitted; however, the
procedure failed to advance, causing a T1 time-over condition
##0671
[RX
]
In V.8 call arrives, the procedure fails to advance to phase 2 after
CM detection, causing a T1 time-over condition
##0672
[TX
]
In V.34 transmission, the procedure fails to move from phase 2
to phase 3 and later, causing a T1 time-over condition
##0673
[RX
]
In V.34 reception, the procedure fails to move from phase 2 to
phase 3 and later, causing a T1 time-over condition
##0674
[TX
]
In V.34 transmission, the procedure fails to move from phase 3
or phase 4 to a control channel or later, causing a T1 time-over
condition
##0675
[RX
]
In V.34 reception, the procedure fails to move from phase 3 or
phase 4 to a control channel or later, causing a T1 time-over
condition
##0705
[TX
]
In CHT transmission, DCN was received after detecting NACK
##0711
[TX
]
In CHT transmission, REJ was received after transmission of an
image signal
##0750
[TX
]
In ECM transmission, no significant signal can be received after
transmission of PPS-NULL, and the allowed number of
procedure signal re-transmissions was exceeded
##0751
[TX
]
In ECM transmission, a signal other than MCF, PPR, or RNR
was received after transmission of PPS-NULL
##0752
[TX
]
In ECM transmission, DCN was received after transmission of
PPS-NULL
##0753
[TX
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-NULL
##0754
[TX
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded after transmission of PPS-NULL
##0755
[TX
]
In ECM transmission, no significant signal can be received after
transmission of PPS-MPS, and the allowed number of procedure
signal re-transmissions was exceeded
##0757
[TX
]
In ECM transmission, DCN was received after transmission of
PPS-MPS
##0758
[TX
]
In ECM transmission, the allowed number of procedure signal
re-transmissions was exceeded or a T5 time-over (60 sec)
condition occurred after transmission of PPS-MPS
Summary of Contents for PC-D320
Page 5: ...III III REVISION HISTORY REVISION CONTENT 0 Original ...
Page 9: ...Chapter 1 General Description ...
Page 10: ......
Page 39: ...Chapter 2 Technical Reference ...
Page 40: ......
Page 49: ...PC D320 PC D340 FAX L400 Chapter 2 Technical Reference 2 9 This page intentionally left blank ...