Océ VarioPrint 6000+ Customer Expectations Document
Version 1
Océ VarioPrint 6000+ Series Customer Expectations Document
Page 19
IMPORTANT
•
If the machine configuration has multiple PIMs or HCS stackers attached, up to
three PIMs can use one power strip or quad box that contains separate 115 V AC
power outlets for each module (on the left side of the engine). Up to three HCS
stackers, can use one power strip or quad box that contains separate 115 V AC
power outlets for each module (on the right side of the engine). The use of power
strips or quad boxes also provides a power source for service tools, such as a
technician’s laptop computer or vacuum; however, it is up to the customer to
provide a separate 115 V AC power source for this purpose.
•
Use only dedicated and properly grounded outlets for the main unit. It is also
strongly suggested to use dedicated and properly grounded outlets for each
optional accessory. Do not use extension cords. The ground connection serves
to provide the internal electronics with a reference voltage. Faulty or poor ground
sources will cause this reference voltage to fall into a range that no longer serves
as a reliable reference voltage. The internal logic and programming of the
VarioPrint 6000+ Series machines will not perform reliably because there is an
insufficient difference between the internal operating signal voltages and the poor
ground reference signal. A qualified electrician can measure and provide the
ground source that the VarioPrint 6000+ Series machines or any computer
controlled office equipment requires.
•
Before installation, confirm that all necessary receptacles are available.
NOTE
The power and dimension specifications for the Print Guard or MEM should be
supplied between the print engine and HCS.