Display
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C15
C16
C17
C18
C21
C22
C23
C24
C25
SERVICE PROGRAMS
Function
Auto exposure sensor monitor-
ing.
Auto exposure adjusting.
Register A-side adjusting.
Blank A-side adjusting.
Curve adjusting.
Register B-side adjusting.
Blank B-side adjusting.
Lens focus 50% adjusting.
Lens focus 200% adjusting.
Fuser temperature adjusting.
Lens home-position sensor ad-
justing.
Mirror home-position sensor
adjusting.
Cassette sensor monitoring.
Nip area cycle starting.
Default auto exposure re/set-
ting.
Copier configuration monitor-
ing.
Control panel LEDs checking.
EEPROM memory initializing.
Automatic shut-off setting.
Main switch shut-off check
Universal cassette code setting.
Lamp brightness 50% adjusting.
Lamp brightness 200% adjust-
ing.
Range
---
0 to 50
0 to 63
0 to 63
0 to 63
0 to 63
0 to 63
0 to 65
0 to 65
130 to
230
0 to 63
0 to 255
---
0/1
0 to 5
---
---
0/1
---
0 to 6
100 to
185
100 to
185
Default
---
25
32
32
32
32
32
---
---
180
32
95
---
1
0
---
---
1
---
0
124
145
Note
0.10 Volt/step
0.25 mm/step
0.25 mm/step
0.25 mm/step
0.25 mm/step
0.25 mm/step
0.0037 %/step
0.15 %/step
[
°
C]
0.113 %/step
0.05 mm/step
Display code
Fixing nip
Enable/diable
Factory only
Turn all LEDs
on
Enable/disable
shut-off copier
For U cassette
Note
A higher setting changes the
lens focus parameter
A higher setting changes the
lens focus parameter
A higher setting changes the
lens position enlargement.
See Table 7-2.
For checkimg fixing pres-
sure after fixing roller re-
placement.
Used to test the main shut
off switch
For setting the universal cas-
sette size, see Table 7-3.
For adjusting exposure lamp
(LA1).
For adjust the exposure
lamp (LA1).