CHAPTER 5 OPERATION TROUBLESHOOTING
5-1
CHAPTER 5 OPERATION TROUBLESHOOTING
A
TROUBLESHOOTING OF MALFUNCTION
1.
"E000, E003 and E004" indication
2.
"E001" indication
Action
Refer to the sub-section
"Fixing roller heater
does not operate."
Replace the DC control-
ler PCB.
End.
Result
No
No
Yes
Check
Cancel the indication. Open the front
cover and delivery assembly door; then,
insert a door switch actuator into the door
switch, and wedge paper into the delivery
paper sensor. Does the fixing roller heater
go ON immediately after power is
switched ON? (Check visually.)
Does the problem disappear when the ther-
mistors (TH1/2) are replaced?
Procedure
1
2
Cause/Problem
area
Thermistors
Action
Refer to the sub-section
"Fixing roller heater
does not operate."
End.
Replace the DC power
supply PCB or DC con-
troller PCB.
Result
No
Yes
No
Check
Cancel the E001 indication. Does the fix-
ing roller heater (H1) go ON immediately
after power is switched ON?
Does the problem disappear when the
main thermistor (TH1) is replaced?
Procedure
1
2
Cause/Problem
area
Thermistor
(TH1)
DC controller
PCB
AC driver/DC
Power supply
PCB
3.
"E030" indication
Action
Refer to the subsection
"Counter does not oper-
ate."
Replace the DC control-
ler PCB.
Result
No
Yes
Check
Does the total counter operate normally?
Procedure
1
Cause/Problem
area
DC controller
PCB
5