![Canon imagerunner advance 8205 Service Manual Download Page 56](http://html.mh-extra.com/html/canon/imagerunner-advance-8205/imagerunner-advance-8205_service-manual_57767056.webp)
imageRUNNER ADVANCE 8200 Series Service Guide
imageRUNNER ADVANCE 8200 Series
Service Guide
November 2012
Page 49
IX.
Servicing Notes
A. Power and Plug Requirements
Canon USA strongly suggests dedicated and properly grounded outlets be
provided for the imageRUNNER ADVANCE 8200 Series devices.
The imageRUNNER ADVANCE 8200 Series
devices require a NEMA 5-20
receptacle for proper operation. Before installation, confirm that the proper
dedicated NEMA receptacles are available for these devices.
Table 13 – Main Unit Power and Plug Requirements
imageRUNNER ADVANCE 8200 Series Main Unit
NEMA 5-20 Receptacle
IMPORTANT
•
We recommend an additional standard 120 V/15 A outlet for service tools,
such as a laptop computer or vacuum that may be used when servicing or
configuring the machine.
•
Use only dedicated and properly grounded outlets for the main unit and
imagePASS. It is also strongly suggested to use dedicated and properly
grounded outlets for each optional accessory. Do not use extension cords.
The ground connection serves to provide the internal electronics with a
reference voltage. Faulty or poor ground sources will cause this reference
voltage to fall into a range that no longer serves as a reliable reference
voltage. The internal logic and programming of the imageRUNNER
ADVANCE 8200 Series machines will not perform reliably because there is
an insufficient difference between the internal operating signal voltages and
the poor ground reference signal. A qualified electrician can measure and
provide the ground source that the imageRUNNER ADVANCE 8200 Series
machines or any computer controlled office equipment requires.
•
Before installation, confirm that all necessary receptacles are available.