COPYRIGHT © CANON ELECTRONICS INC. 2012
CANON P-208 FIRST EDITION
5-43
CHAPTER 5 TROUBLESHOOTING
VI. AFTER REPLACING PARTS
Some of the parts used in this machine
require adjustments and settings after being
replaced or disassembled and reassembled.
You should check the feed and images
after replacing parts or reassembling and
reassembling the machine.
Control PCB
1) Execute [All] in service mode.
2) Change the value in the [Counter] in ser-
vice mode.
3) Input the serial number into [Serial num-
ber] in service mode.
Reading Unit
Execute [All] in service mode.
Registration Related Parts
If problems occur in the leading edge or
trailing edge positions of images
scanned after replacing or reassembling
registration related parts, execute [Reg-
ist sensor] and then execute [Registra-
tion (Auto)] in service mode. Further-
more, execute [Registration (Manual)] if
necessary.