16
2.8 Disassembly of OPERATION FPC ASS'Y
(1) Disengage the dowel A, and then detach the KEY SHEET.
Note: Reuse of the KEY SHEET is not allowed.
(2) Disconnect the CN1002, disengage the dowels B, A and C and the hook, then slightly set the OPERATION FPC
ASS’Y away from the main unit.
(3) Disconnect the CN102, and then detach the OPERATION FPC ASS'Y.
(2)
OPERATION
FPC ASS’Y
KEY SHEET
(2)
(1)
(3)
(3)
Dowel C
Dowel B
Dowel A
Hook
Hook
CN102
CN1002
Tweezers