5-25
Function
Operational verification
DIP switch setting
T05-401-03
Contents
Pickup motor operation test
Press the push switch (PSW1) to let the
ADF run continuously. Run the ADF
without paper loaded, since a timing has
not been detected.
Forwarding
(70=>140=>280=>0)
Reversing
(70=>140=>280=>0)
Solenoid actuation test
There are two modes of operation avail-
able: ON/OFF mode, in which the sole-
noid turns on and off alternately each time
the push switch (PSW1) is pressed, and
continuous mode, in which the solenoid
turns on only while PSW1 is pressed.
Locking solenoid
(ON/OFF)
Stamp solenoid (ON/
OFF)
Locking solenoid
(continuous)
Stamp solenoid (con-
tinuous)