COPYRIGHT © 1999 CANON INC. CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
13-105
CHAPTER 13 TROUBLESHOOTING
Cause
------------
Toner
concentration
sensor
DC driver PCB,
CPU PCB
Stray light
Black toner
concentration
sensor
Photosensitive
drum
DC driver PCB,
CPU PCB
Action
Go to step 7.
End.
· When you have
replaced the toner
concentration sensor,
be sure to replace the
developer also.
Replace the DC driver
PCB or the CPU PCB.
Mount the transfer unit
front cover.
Replace the black toner
concentration sensor.
· If you have replaced
the toner concentration
sensor, be sure to
replace the developer
also.
End.
Replace the DC driver
PCB or the CPU PCB.
Step
5
6
7
8
Yes/No
YES
YES
NO
YES
NO
YES
NO
Checks
Is E020 indicated for Bk? (Is it
E020=04xx?)
Replace the toner concentration
sensor of the color for which E020
is indicated. Is the problem
corrected?
Is the copier's front cover left open
after the transfer unit front cover is
removed (i.e., is the black toner
concentration sensor subjected to
stray light)?
Replace the photosensitive drum. Is
the problem corrected?
Summary of Contents for CLC 1120
Page 6: ......
Page 20: ......
Page 22: ......
Page 48: ......
Page 94: ......
Page 96: ......
Page 114: ......
Page 134: ......
Page 136: ......
Page 152: ......
Page 242: ......
Page 346: ......
Page 374: ......
Page 376: ......
Page 412: ......
Page 452: ......
Page 454: ......
Page 517: ......
Page 881: ......
Page 893: ......
Page 895: ......
Page 899: ......