(1)
CPU+I/O-CONT P.C.B.
© First remove rear and upper covers (see paragraph
3.1 of Chapter 3). Then, disconnect CRT internal
cable from CRT-C0NT2-B/W P.C.B.
© Disconnect grounding cables from individual P.C.B.
and chassis of power supply unit.
(3) Disconnect FDD internal cable from CPU+I/O-CONT
P.C.B.
© Remove CPU+I/O-CONT P.C.B from MAIN UNIT.
© After confirming switch set position for CPU+I/O-
CONT P.C.B (see paragraph 4.2.2), connect it in
reverse order of above steps.
CONT 2-B/W P.C.B.
First remove rear and upper covers (see paragraph
3.1). Then, disconnect CRT internal cable from
CRT-C0NT2-B/W P.C.B.
Disconnect the grounding cables, which are extending
from individual P.C.Bs, from the chassis of the power
supply unit.
Remove CRT-C0NT2-B/W P.C.B from MAIN UNIT.
Connect spare CRT-C0NT2-B/W P.C.B in reverse order
of above steps.
Color Display|
(1) CPU+-I/O-CONT P.C.B
© First remove rear and upper covers (see paragraph 3.1).
Then, disconnect CRT internal cable from CRT unit.
© ^ ©
Same as for B/W display
(2) CRT-
G>
(D
©
5-2
Summary of Contents for AS-100C
Page 1: ...Canon FIELD SERVICE MANUAL ...
Page 26: ...2 2 5 FDD Media Canon specified MDD 512DD 512B sector 2 3 ...
Page 30: ...ICURRENT LÖÖPl Available soon 2 7 ...
Page 39: ...3 3 5 FDD 3 3 1 External View Housing plate Fig 3 3 1 Fig 3 3 2 3 5 ...
Page 41: ...3 4 8 FDD 3 4 1 External View Housing Fig 3 4 1 Fig 3 4 2 3 7 ...
Page 43: ...3 5 PRINTER Refer to PRINTER TECHNICAL GUIDE 3 9 ...
Page 47: ... 2 KEYBOARD 3 5 FDD 4 3 ...
Page 48: ... 8 FDD 4 4 ...
Page 100: ...8 FDD Fuse 1 Replace two 5A fuses 8 FDD as In Fig 5 5 7 5 23 ...
Page 107: ...Chapter 7 Troubleshooting 7 1 At System Up 7 1 ...
Page 129: ...Chapter 8 Appendix 8 1 Unit Configuration and General Wiring ...
Page 130: ...8 1 Unit Configurations and General Wiring 8 1 POWER SWITCH ...
Page 135: ...Fig 8 1 6 8 FDD For 115 120 230 240V POWER SWITCH ...
Page 136: ...CANON INC COPYRIGHT g 198 BY CANON INC Printed in Japan Feb 1983 E Y 8 6 0 7 2 2 2 2 ...