![background image](http://html1.mh-extra.com/html/canon/7215-lv-xga-lcd-projector/7215-lv-xga-lcd-projector_specification_4019829021.webp)
Basic Serial Functional Specification for LV-5210/7215/7210
7.3.9 “24”
[CR]
Status: Processing Power Save
・
Cooling Down
Cooling down by the power management function in the e setting menu.
The control command is invalid.
This Power Save
・
Cooling Down moves to Power Save after the cooling down time.
Status:
No signal
POWER
SAVE
・
COOLING
DOWN
POWER SAVE
Response:
”00”
“24”
“04”
After 5 minutes with no signal after about 90 seconds
7.3.10 “04” [CR]
Status of Power Save
The status is Power Save by the Power management function in setting menu.
7.4 Input Mode Read COMMAND
COMMAND “CR1” [CR]
Detail
Get selected Input No.
Acceptable
“
%
1” [CR]
%
1
“1” = Computer1 is selected
“2” = Computer2 is selected
“3” = Video is selected.
Response
Unacceptable “?” [CR]
7.5 Lamp Time Read COMMAND
COMMAND “CR3” [CR]
Detail
Get total lamp running hours.
Acceptable
“
%
1” [CR]
%
1
Show as 4 digits
Ex.: “0410”[CR]
・・・・
410 hours
Response
Unacceptable “?” [CR]
Page