8
8
8-16
8-16
Service Mode > Details of Service Mode > #NUMERIC > Numerical Parameter Composition
Service Mode > Details of Service Mode > #NUMERIC > Numerical Parameter Composition
#NUMERIC
■
Numerical Parameter Composition
No.
Item
Range of settings
002 RTN transmission condition (1)
1% to 99%
003 RTN transmission condition (2)
2 to 99 item
004 RTN transmission condition (3)
1 to 99 lines
005 NCC pause time length (pre-ID code)
1 to 60 sec
006 NCC pause time length (post-ID code)
1 to 60 sec
008 Time from Right After Dialing by Auto-dialing to Start of
Communication
1 to 65 sec
010 line condition identification time length
0 to 9999 (10 msec)
011 T.30T1 timer (for reception)
0 to 9999 (10 msec)
012 The maximum number of received lines
0 to 65535 (line)
* Unlimited in the case
of 0
013 T.30 EOL timer
500 to 3000 (10 msec)
015 hooking detection time length
0 to 999
016 time length to first response at time of fax/tel switchover
0 to 9
017 pseudo RBT signal pattern ON time length
0 to 999
018 pseudo RBT signal pattern OFF time length (short)
0 to 999
019 pseudo RBT signal pattern OFF time length (long)
0 to 999
020 pseudo CI signal pattern ON time length
0 to 999
021 pseudo CI signal pattern OFF time length (short)
0 to 999
022 pseudo CI signal pattern OFF time length (long)
0 to 999
023 CNG detection level at time of fax/tel switchover
0 to 7
024 pseudo RBT transmission level at time of fax/tel switchover
10 to 20
0 to 20 (120/230V)
025 Answering machine connection function signal detection time
0 to 999
027 preamble detection time length for V21 low-speed flag
20 (x 10ms)
051 Hooking detection threshold
053 Setting of DTMF call origination count at remote reception of fax
055 acquisition period of environmental log data
0 to 480 (60min)
(0: no data acquisition)
056 Display the type of soft counter 1
101 (Fixed)
057 Display the type of soft counter 2
0 to 999
058 Display the type of soft counter 3
0 to 999
059 Display the type of soft counter 4
0 to 999
060 Display the type of soft counter 5
0 to 999
061 Display the type of soft counter 6
0 to 999
062
Communication termination timer at SMTP transmission protocol
level
0 to 65535 sec
063
Communication termination timer at SMTP reception protocol level 0 to 65535 sec
064
Communication termination timer at POP reception protocol level
0 to 65535 sec
065
Communication termination timer at FTP transmission protocol level 0 to 65535 sec
No.
Item
Range of settings
066
Communication termination timer from start to completion of the
transmission of SMTP transmission data
0 to 65535 sec
067
Communication termination timer from start to completion of the
reception of SMTP reception data
0 to 65535 sec
068
Communication termination timer from start to completion of the
reception of POP reception data
0 to 65535 sec
069
Communication termination timer from start to completion of the
transmission of FTP transmission data
0 to 65535 sec
074 e-RDS RGW port number
1 to 65535
default: 443
075 Interval of transmission for e-RDS 3rd party
1 to 168 (hours)
default: 24
T-8-28
Summary of Contents for 1750
Page 12: ...Update Firmware XXV Volume Control XXV Backup Data XXVI...
Page 17: ...1 1 Product Overview Product Overview Product Lineup Features Specifications Parts Name...
Page 235: ...7 7 Error Code Error Code Overview Error Code Jam Code Alarm Code...
Page 250: ...8 8 Service Mode Service Mode Outline Details of Service Mode...
Page 333: ...Service Tools General Timing Chart General Circuit Diagram List of User Mode Appendix...