background image

Do not place clothing or other flammable material on or near the heater.
Keep curtains, clothing, furniture and other flammable materials at least
900mm from front and sides of the heater.

At the owners discretion curtain clearances can be less than 900mm as
long as they are restrained from the front, top and sides of the heater.

The manufacturer takes no responsibility if curtain clearance is less than
900mm and not restrained.

For full safety warning information, Refer to Heater User Instructions.

Page 3.

This appliance is not intended for use by persons

(including children) with reduced physical, sensory or

mental capabilities, or lack of experience and knowledge,

unless they have been given supervision or instruction

concerning use of the appliance by a person responsible

for safety. Children should be supervised to ensure that

they do not play with the appliance.

Features of your thermostat model heater:

If the controller is turned on and there is a requirement for heating, the
heater will start up on Low Fire and Low Fan and operate for approximately
3 minutes.

The heater will then go to your preset desired temperature functions on
the remote controller

Once the selected room temperature has been reached, the heater will
go to Low Fire and Low Fan.

The full description on the operation of the heater is described in more
detail in the following section.

This heater features a safety interlock mode to prevent accidental or
inappropriate activation of the hand held remote control unit. It requires
both “

and “

buttons be pressed at the same time to turn on the

controller.

PWR”

OK”

Page 16.

Function

Action                                                                     Page

Switch on/off

Change
between
manual and
automatic
mode.

Increase /
decrease
temperature.

Set the clock
and day of
the week.

Program the
thermostat

Press and release ‘

button.

A/M ‘

Press and release

button.

‘UP ‘ or ‘DOWN ‘

With the thermostat off, press and hold the ‘ ’
button until the time, hour and

flash.

Press and release the ‘

or ‘

buttons

to increase or decrease the hour setting.

Press and hold for the hour to increase or
decrease 1 hour every 0.5 seconds.

Press ‘

and set the minute setting similarly.

Press ‘

and press and release the ‘

’ or

’ buttons to change the day of the week.

T

AM/PM

UP ’

DOWN ’

OK ’

OK ’

UP

DOWN

With the thermostat off, press and hold
the ‘ ’ button. Program 1 can now be set.

To select Monday press ‘

, or press and

release ‘

or ‘

to change the day of

the week, or to switch to the weekday or
weekend setting.

To set the period starting time, set the hour and
minute setting similarly to setting the clock.

Press ‘

. Press and release the ‘

or

button to increase or decrease the

temperature setting by 1°C.
Press ‘

’. Program 2 can now be set.

Repeat the programming process for the 4
periods.

P

OK ’

UP ’

DOWN ’

OK ’

UP ’

DOWN’

OK

8

9

9

8

10

Press ‘

&

buttons at same time

(then release)

PWR’

‘OK’

SAFETY WARNINGS

Quick reference table

Summary of Contents for GMK10025

Page 1: ...lease leave instructions with the owner Cannon For service to this appliance or spare parts contact the CANNON distributor Email aftersalesservice sampfordixl com au Date installed Compliance Certificate No Sampford IXL Spare Parts Phone 1300 727 421 Fax 1300 727 425 PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS PRODUCT Part Number F3754_D ...

Page 2: ...le 16 Back Up Switch 17 Service 18 Features 4 6 Frequently asked questions 15 Battery type 2 X AA batteries Battery life approximately 12 months Transmission frequency 433 92 Mhz Dimensions 140MM x 80mm x 20mm Page 1 NOTES CONTENTS INITIAL START UP 1 Disconnect heater from power supply 2 Fitted batteries to remote thermostat unit 3 connect Heater back to power supply and point Remote Thermostat at...

Page 3: ...lease PWR OK A M Press Button to select Manual mode Room temperature is shown at top of screen Selected temperature shown at mid screen The heater will only operate if the actual room temperature is lower than the required temperature Manual Mode The required temperature can be selected by using or buttons A M UP DOWN To start heater Select and buttons and press them together then release Select A...

Page 4: ... of the heater is described in more detail in the following section This heater features a safety interlock mode to prevent accidental or inappropriate activation of the hand held remote control unit It requires both and buttons be pressed at the same time to turn on the controller PWR OK Page 16 Function Action Page Switch on off Change between manual and automatic mode Increase decrease temperat...

Page 5: ...uto or Manual The heater on start will operate on Low Fire and fan for approx 3 minutes The heater will then go to your preset desired settings on remote thermostat As the preset temperature is reached the heater will go to Low Fire and Low Fan If the preset temperature is exceeded the burner is extinguished and the fan will run on at low setting for approximately 3 min If room temperature is stil...

Page 6: ... The thermostat temperature display can be set to C or F The default is C With the thermostat off press the following sequence of buttons P T T A M Please note thermostat settings need to be actioned within a period of 15 seconds total 2 1 Leave the remote thermostat in the off or stand by position the room temperature and time only will be displayed 2 The heater must be turned off at its switch l...

Page 7: ...and minutes AM or PM The time is displayed when the thermostat is on or off Displays the current day of the week The day is displayed when the thermostat is on or off Displays the current temperature C is the default but F is available The temperature range is 7 C to 32 C When the thermostat is on the programmed set temperature will be displayed When the thermostat is off only the room temperature...

Page 8: ... 2 or more seconds when thermostat is off Indicates the programming mode must press and hold for 2 or more seconds when thermostat is off Functions Button Function Description PWR OK UP DOWN PWR UP DOWN OK Switches the thermostat on If the thermostat is off pressing and releasing the PWR and OK button together will turn the thermostat on to the most recently selected working mode On Accepts the cu...

Page 9: ... set Page 8 Note Use the outer edge of buttons to toggle through functions With the thermostat off press and hold the button for 2 seconds or longer to initiate programming the time the setting and the AM PM will flash T Time hour Page 11 Setting the period starting time The hour and AM PM settings will now flash To set the P1 starting time press and release the and button to increase or decrease ...

Page 10: ...d up or down similar to operating in mode However whenever the thermostat changes to a new time period the temperature will be automatically according to that period s setting automatic A M manual reset automatic Page 9 Programming Each day of the week can be programmed individually for periods P1 P2 P3 and P4 making a total of 28 programmed periods Alternatively a weekday program can be set so th...

Reviews: