GENERAL
THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS.
AS 5601, MUNICIPAL BUILDINGS CODES, ELECTRICAL
WIRING REGULATIONS AND ANY OTHER STATUTORY
REGULATIONS.
TO CONFORM WITH THE AGA APPROVAL REQUIREMENTS
THE SPACERS MUST BE PERMANENTLY FITTED TO MAINTAIN THE
REQUIRED CLEARANCE FROM COMBUSTIBLE MATERIALS.
THESE INSTRUCTIONS TO BE READ IN CONJUNCTION WITH THE
HEATER INSTALLATION BOOKLET.
THIS HEATER MUST BE INSTALLED CORRECTLY TO PROVIDE
SAFE AND RELIABLE OPERATION.
PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS AND TO
FAMILIARIZE YOURSELF WITH THE CORRECT INSTALLATION
METHODS.
CORRECT FLUE DESIGN AND ALLOWANCE FOR VENTILATION
MUST BE CONSIDERED.
AVOID THE USE OF FLUE BENDS IF POSSIBLE.
ALWAYS ALLOW FOR THE COMPLETE REMOVAL OF THE HEATER
WITHOUT ANY DIFFICULTIES AND MAKE SURE THAT THE FLUE IS
RIGID AND SELF SUPPORTING. THE BOTTOM LENGTH OF THE FLUE
MUST FIT INSIDE OF THE ADAPTING
PIECE. THE FLUE
ADAPTING PIECE MUST BE A SLIP FIT OVER THE RECTANGULAR
SPIGOT ON THE HEATER.
MAKE SURE THAT THE HEATER IS FULLY COMMISSIONED AND
BE CERTAIN TO CONDUCT A TEST OF THE INTEGRITY OF THE
FLUE OPERATION, TAKING INTO ACCOUNT ANY INFLUENCES
CREATED BY RANGE HOODS, EXHAUST FANS, CENTRAL HEATING
ETC.
TO AVOID ANY UNNECESSARY DELAYS AND INCONVENIENCE TO
YOUR CUSTOMER, LEASE CONTACT OUR TECHNICAL SUPPORT
SECTION IF THE INSTALLATION IS UNUSUAL AND REQUIRES
FURTHER ADVICE OR ASSISTANCE.
SPIGOT
Page 1.
INSTALLATION INTO A COMBUSTIBLE ENCLOSURE
( SINGLE SKIN FLUE )
METHOD B
Page 8.
FIG 7.
610 mm BETWEEN
TOP OF COWL AND
NEAREST PART OF ROOF
FLUE COWL
APPROVED
TO AG604
FLUE CLAMP
FLASHING
ROOF CLADDING
R
E
AFT
RS
PROVIDE
CLEARANCE
AROUND
CEILING JOISTS
FALSE ENCLOSURE BY
OTHERS TO NORMAL
BUILDING PRACTICE
MAINTAIN 25mm
CLEARANCE
FROM ALL
COMBUSTIBLES
INSULATION
BLANKET
HEATER
100 mm DIA
SINGLE SKIN
FLUE
FLUE TO FIT INSIDE
OF SPIGOT
FIT TWO LENGTHS OF
VERTICAL FLUE (1.8 M)
BEFORE FITTING ANY
BENDS. IF BENDS ARE
USED, FIT INSIDE OF
FLUE PIPE.
USE NO MORE THAN
TWO BENDS IN THE
TOTAL FLUE RUN AND
MAINTAIN AT LEAST
250 mm OF STRAIGHT
FLUE PIPE BETWEEN
THE BENDS.
FLUE TO BE
SUPPORTED
INDEPENDENTLY
OF THE APPLIANCE
FLUE CONNECTION.
125
505 MAX
RECTANGULAR TO ROUND 90 DEG TRANSITION
ADAPTOR SUPPLIED WITH MOCK KIT.
MAKE SURE THERE IS ADEQUATE VENTILATION IN ROOM.