GENERAL

THIS HEATER SHALL ONLY BE INSTALLED BY AN AUTHORIZED 
PERSON. THIS APPLIANCE SHALL BE INSTALLED IN ACCORDANCE 
WITH THE MANUFACTURERS INSTALLATION INSTRUCTIONS.
AS 5601, MUNICIPAL BUILDINGS CODES, ELECTRICAL 
WIRING REGULATIONS AND ANY OTHER STATUTORY 
REGULATIONS.

TO CONFORM WITH THE AGA APPROVAL REQUIREMENTS
THE SPACERS MUST BE PERMANENTLY FITTED TO MAINTAIN THE 
REQUIRED CLEARANCE FROM COMBUSTIBLE MATERIALS.

THESE INSTRUCTIONS TO BE READ IN CONJUNCTION WITH THE
HEATER INSTALLATION BOOKLET.

THIS HEATER MUST BE INSTALLED CORRECTLY TO PROVIDE
SAFE AND RELIABLE OPERATION.

PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS AND TO
FAMILIARIZE YOURSELF WITH THE CORRECT INSTALLATION
METHODS.

CORRECT FLUE DESIGN AND ALLOWANCE FOR VENTILATION
MUST BE CONSIDERED.

AVOID THE USE OF FLUE BENDS IF POSSIBLE.

ALWAYS ALLOW FOR THE COMPLETE REMOVAL OF THE HEATER
WITHOUT ANY DIFFICULTIES AND MAKE SURE THAT THE FLUE IS
RIGID AND SELF SUPPORTING. THE BOTTOM LENGTH OF THE FLUE 
MUST FIT INSIDE OF THE ADAPTING 

PIECE. THE FLUE

ADAPTING PIECE MUST BE A SLIP FIT OVER THE RECTANGULAR
SPIGOT ON THE HEATER.

MAKE SURE THAT THE HEATER IS FULLY COMMISSIONED AND
BE CERTAIN TO CONDUCT A TEST OF THE INTEGRITY OF THE
FLUE OPERATION, TAKING INTO ACCOUNT ANY INFLUENCES
CREATED BY RANGE HOODS, EXHAUST FANS, CENTRAL HEATING
ETC.

TO AVOID ANY UNNECESSARY DELAYS AND INCONVENIENCE TO
YOUR CUSTOMER, LEASE CONTACT OUR TECHNICAL SUPPORT
SECTION IF THE INSTALLATION IS UNUSUAL AND REQUIRES
FURTHER ADVICE OR ASSISTANCE. 

SPIGOT 

Page 1.

INSTALLATION INTO A COMBUSTIBLE ENCLOSURE

( SINGLE SKIN FLUE )

METHOD B

Page 8.

FIG 7.

610 mm BETWEEN
TOP OF COWL AND
NEAREST PART OF ROOF

FLUE COWL
APPROVED
TO AG604

FLUE CLAMP

FLASHING

ROOF CLADDING

R

E

AFT

RS

PROVIDE
CLEARANCE 
AROUND
CEILING JOISTS

FALSE ENCLOSURE BY
OTHERS TO NORMAL
BUILDING PRACTICE

MAINTAIN 25mm 
CLEARANCE 
FROM ALL 
COMBUSTIBLES

INSULATION
BLANKET

HEATER

100 mm DIA
SINGLE SKIN 
FLUE

FLUE TO FIT INSIDE
OF SPIGOT

FIT TWO LENGTHS OF 
VERTICAL FLUE (1.8 M)
BEFORE FITTING ANY
BENDS. IF BENDS ARE
USED, FIT INSIDE OF
FLUE PIPE.
USE NO MORE THAN
TWO BENDS IN THE
TOTAL FLUE RUN AND
MAINTAIN AT LEAST
250 mm OF STRAIGHT
FLUE PIPE BETWEEN
THE BENDS.

FLUE TO BE 
SUPPORTED
INDEPENDENTLY
OF THE APPLIANCE
FLUE CONNECTION.

125

505 MAX

RECTANGULAR TO ROUND 90 DEG TRANSITION 
ADAPTOR SUPPLIED WITH MOCK KIT.

MAKE SURE THERE IS ADEQUATE VENTILATION IN ROOM.

Summary of Contents for CANTERBURY CANTIB-02-LP

Page 1: ...O SUIT MOCK FIREPLACE INSTALLATIONS INSTALLATION INSTRUCTIONS FOR FITMENT INTO A COMBUSTIBLE ENCLOSURE This heater is for use with Natural and Propane gases Read these instructions in conjunction with heater installation instructions SPACE HEATER GAS LOG FIRE ...

Page 2: ...COMMENDATIONS age 2 MOCK CAVITY DIMENSIONS age 3 P 4 ag OVERALL DIMENSIONS OF INSERT CABINET P e ge FITMENT OF SPACER BRACKETS AND BLANKET Pa 5 INSTALLATION INTO WALL CAVITY METHOD A Page 6 7 P INSTALLATION INTO COMBUSTIBLE CAVITY METHOD B age 8 P MAINTENANCE age 9 ...

Page 3: ...ELF WITH THE CORRECT INSTALLATION METHODS CORRECT FLUE DESIGN AND ALLOWANCE FOR VENTILATION MUST BE CONSIDERED AVOID THE USE OF FLUE BENDS IF POSSIBLE ALWAYS ALLOW FOR THE COMPLETE REMOVAL OF THE HEATER WITHOUT ANY DIFFICULTIES AND MAKE SURE THAT THE FLUE IS RIGID AND SELF SUPPORTING THE BOTTOM LENGTH OF THE FLUE MUST FIT INSIDE OF THE ADAPTING PIECE THE FLUE ADAPTING PIECE MUST BE A SLIP FIT OVER...

Page 4: ...HEATER WILL NEED TO BE CONSTRUCTED THE HEATER MUST SIT ON A SOLID SEALED BASE AND THE ENCLOSURE MUST BE SEALED FROM ANY DRAUGHTS AND BE INSULATED AS NECESSARY TO ELIMINATE LOW TEMPERATURES OUR BROCHURE ILLUSTRATES AN ENCLOSURE CONSTRUCTED TO AN EXISTING ROOM WITH A SOLID FLOOR AND CEILING ANY OTHER ENCLOSURE MUST HAVE THE SAME CHARACTERISTICS OF BEING SEALED FROM ANY DRAUGHTS AND SUITABLY INSULATE...

Page 5: ...USTIBLE SURFACES 20 mm CLEARANCE FROM BOTH TOP AND SIDE SURFACES 50 mm CLEARANCE FROM REAR 100 mm CLEARANCE BETWEEN SIDE OF THE HEATER FRONT AND COMBUSTIBLES ADDITIONAL CLEARANCES ARE SPECIFIED IN THE HEATER INSTALLATION INSTRUCTION BOOKLET FIG 10 FIG 2 DEPTH OF CAVITY HEATER ADAPTOR FLUE CLEARANCE MIN 450 mm 300mm 125mm 25mm MAX 505 mm 300mm 125mm 80mm ...

Page 6: ... DEPTH WITH TRANSITION ADAPTOR FITTED 425 mm 620 mm 350mm 425mm THE HEATER FOR INSTALLATION INTO A MOCK FIREPLACE IS SUPPLIED WITH THE FOLLOWING PARTS SEE FIG 5 F1417 FLUE TRANSITION ADAPTOR F1404 REAR BRACKETS F1405 TOP SIDE SPACER BRACKETS F1406 INSULATION BLANKET F2663 INSTRUCTION BOOKLET 1 OFF 2 OFF 4 OFF 1 OFF 1 OFF ...

Page 7: ...R CABINET ON DIAGONAL CORNERS AS SHOWN SEE FIG 5 3 POSITION INSULATION BLANKET ON HEATER TOP ALIGNED WITH EDGES SECURE WITH MASKING TAPE AS SHOWN SEE FIG 5 FIXING SCREWS No8 x 3 8 SELF TAPPING D I A G O N A L C O R N E R S 563 mm TO ENTRE LINE C O A C R E R D I A G N L O N S TOP SIDE BRACKETS ATTACHED INSULATION TO TOP OF THE HEATER WITH MASKING TAPE FIG 5 TRANSITION ADAPTOR REAR BRACKET INSULATIV...

Page 8: ...THROUGH HEADER FLANGES AT STUD CENTRES AND USE CLOUTS OR SCREWS TO ATTACH TO WALL 6 MEASURE DISTANCE FROM FLOOR TO TOP OF FLUE OUTLET OF THE HEATER 7 ADJUST ELBOW TO THE DISTANCE MEASURED PLUS 2 mm AND TIGHTEN SCREW ENSURE FLUE ELBOW IS HORIZONTAL 8 BEND TABS IN AT THE BASE OF THE TWIN SKIN FLUE AND LOWER TWIN SKIN FLUE DOWN THE WALL CAVITY 9 SLIDE TOP PLATE FLUE SUPPORT OVER TWIN SKIN FLUE CENTRA...

Page 9: ...TE FLUE SUPPORT FLUE ADAPTER FLASHING FLUE CLAMP FLUE COWL APPROVED TO AG604 ROOF CLADDING 100 mm DIA FLUE PIPE MAINTAIN 25 mm CLEARANCE BETWEEN FLUE AND WOODWORK WALL CLADDING 12 mm FROM BOTTOM OF WALL CLADDING TO TOP OF HEATER MEASURE DISTANCE FROM FLOOR TO TOP OF HEATER FLUE OUTLET PLUS 2 mm COWL FIT 3 SCREWS SMALL DIA END WITH SWAGE TOP PLATE FLUE SUPPORT FLUE ADAPTER SINGLE SKIN FLUE Page 7 F...

Page 10: ...FROM ALL COMBUSTIBLES INSULATION BLANKET HEATER 100 mm DIA SINGLE SKIN FLUE FLUE TO FIT INSIDE OF SPIGOT FIT TWO LENGTHS OF VERTICAL FLUE 1 8 M BEFORE FITTING ANY BENDS IF BENDS ARE USED FIT INSIDE OF FLUE PIPE USE NO MORE THAN TWO BENDS IN THE TOTAL FLUE RUN AND MAINTAIN AT LEAST 250 mm OF STRAIGHT FLUE PIPE BETWEEN THE BENDS FLUE TO BE SUPPORTED INDEPENDENTLY OF THE APPLIANCE FLUE CONNECTION 125...

Page 11: ...MAINTENANCE IF YOUR HEATER REQUIRES ATTENTION CONTACT SAMPFORD AND STAFF PTY LTD ON PH 1300 727 421 or FAX 1300 727 425 Page 9 7 ...

Page 12: ...REF F2663 E CANTERBURY IB MOCK INSTALLATION INSTRUCTION CDR REVISION E DATED APRIL 2007 ...

Reviews: