THE ACTIVE 5  USER INSTRUCTIONS

DATE: FEB 1997

1.0 SETTING

1.1  FULL SET

To start the exit procedure ensure all alarmed zones are clear and enter your four digit user code,

the speaker will emit a steady sound and the exit time will start. Leave the building by the approved exit

route and close the final exit door. Wait outside the door until the speaker has stopped to indicate that the

panel has armed. The DAY LED will now be extinguished. If however you need to set the system by using

a terminator button or lock then operate from the outside of the system now.

If any zones are in fault the speaker will give a pulsed tone and the LED for that zone will be lit.

Return to the panel and press the "#" key or enter the user code to abort the exit procedure. Investigate the

fault and correct if possible, then start the exit procedure again. If any zone on the exit route is open (door

open or detector tripped) then the speaker will give a pulsed tone on exit but should go to a steady tone

when the zone closes If you are unable to correct the fault contact your Installer. If you do not complete the

exit procedure before the exit time runs out an internal alarm will occur. Enter your user code to stop the

alarm. See section 3.4 to reset the system.

1.2 NIGHT SET. Usually when you go to bed.

Start the exit procedure as for full set as above. Then press the "*" key followed by the "0" key.

The speaker will change to a lower pitched tone and the LED's for any zones programmed to be isolated in

night set will flash. The programmed Night set exit time will be selected and the exit procedure will

continue. If your system does not allow Night set an error tone will sound and the exit procedure will be

aborted. Again if the panel sets the  DAY LED will extinguish.

1.3 HOME SET. If you want to set during the evening.

Start the exit procedure as for full set as above. Then press the "*" key followed by the "6" key.

The speaker will change to a lower pitched tone and the LED's for any zones programmed to be isolated in

home set will flash. The programmed night set exit time will be selected and the exit procedure will

continue. If your system does not allow home set an error tone will sound and the exit procedure will be

aborted. Again, the DAY LED will extinguish.

1.4 MANUAL ISOLATION

Start the chosen exit procedure as above. Then press the "*" key followed by the zone number you

require to isolate. If more than one zone is required then press the * button followed by the next zone

number and so on until you have completed your choice. If the zone is isolated the LED for the required

zone will flash and the exit procedure will continue. If you hear an error tone (dah dah) then the required

zone may not be programmed for you to isolate. Contact your Installer with regards to making this zone

“Isolate permit”.

2.0 UNSETTING

Enter by your usual route, the Speaker will begin to sound. Do not stop, go directly to the keypad.

Enter the four digit code, the speaker will stop and the control panel will return to the 'DAY' mode. If the exit

time has less than 10 seconds remaining the speaker will emit a quick pulsing sound to indicate "HURRY

UP".

3.0 FAULTS

3.1 TAMPER FAULTS DURING AN UNSET PERIOD. (DAY MODE)

A tamper fault during the day is indicated by the internal speaker and the tamper LED. Enter your

four digit user code to stop the speaker, the speaker will now change to a low level two tone alternating

sound to indicate that there is a "RESET REQUIRED". Press the # key to reset the system.

3.2 ALARMS DURING THE SET PERIOD

 Enter your four digit user code to unset the system. The LED display will indicate which zone/s

caused the alarm. See section 3.4  to reset the panel.

3.3 PERSONAL ATTACK ALARMS

Enter your four digit user code to stop the speaker. Reset the personal attack button with the key

provided (if needed). See section 3.4 to reset the system.