![C&J DGT 5000 Owners Book Download Page 20](http://html1.mh-extra.com/html/candj/dgt-5000/dgt-5000_owners-book_3070019020.webp)
LT5032 (01:05-08)
20
C&J DGT 5000
Installation Instructions
SECTION TEN
Maintenance Instructions Cont.
REPLACEMENT OF OXY-PILOT ASSEMBLY
NOTE:
If the pilot assembly is replaced it must be replaced by an identical unit from the same
manufacturer and replaced as a complete unit it is a NON SERVICABLE ITEM.
1.
Repeat operations 1-5 for removal of gas control.
2.
Disconnect the pipe from the gas control to the pilot burner
3.
Disconnect the thermocouple connection from the electronic control box.
4.
Remove ignition lead from pilot assembly.
4.
Remove the two screws securing the oxy-pilot to the burner.
5.
Before replacing ensure the code number for Oxy-Pilot replacement is suitable.
6.
Re-assemble the in reverse order and check assembly for gas soundness.
7.
Turn on the gas supply, check for gas soundness and re-commission appliance
REPLACEMENT OF CONTROL UNIT (EDB)
1. Repeat operations 1-5 for removal of gas control.
2. Disconnect leads from control unit and remove securing bolts.
3. Re-assemble in the reverse order.
Turn on the gas supply, check for gas soundness and re-commission appliance.
SECTION NINE
Wiring Diagram
Summary of Contents for DGT 5000
Page 22: ...LT5032 01 05 08 22 Blank Page...