background image

 

 

 

 

Operation of wireless remote control 

Guide for operation- General operation

 

1. After powered on, press ON/OFF button, the unit will start to run.(Note: When 

it is powered on, the guide louver of main unit will close automatically.)

 

2. Press MODE button, select desired running mode.

 

3. Pr or - button, to set the desired temperature. (It is unnecessary 

to set the temp. at AUTO mode.)

 

4. Pressing FAN button, set fan speed, can select AUTO, FAN 1, FAN 2, 

FAN 3 or FAN 4.

 

5. Pressing SWING button, to select the swing.

 

Guide for operation- Optional operation

 

1. Press SLEEP button, to set sleep.

 

2. Press TIMER button, can set the scheduled timer on or timer off.

 

Introduction for special function

 

About AUTO RUN

 

When AUTO RUN mode is selected, the setting temperature will not be displayed on the 

LCD, the unit will be in accordance  with the room temp. automatically to select the suitable 

running method and to make ambient comfortable.

 

About  LOCK

 

Under switch-on or switch-off state, you may hold "+" and "-" key simultaneously to lock and 

unlock the keypad. When locked, the display will show the LOCK icon, in which case the 

lock icon will flash three times upon operation of any key. After the keypad is unlocked, the

 

lock icon on the display will be hidden. After being energized, the default is unlock.

 

About switch between Fahrenheit and Centigrade

 

Under switch-off state, you may hold "-" and "MODE" keys simultaneously to switch between

 

℃ 

and 

℉ 

.

 

About  Lamp

 

Under switch-on or switch-off state, you may hold "+" and "FAN" key simultaneously for 3 seconds 

to set the lamp on or off and send the code. After being energized, the lamp is defaulted on.

 

About  Blow over heat

 

When the unit is running in Heat mode or Auto Heat mode, compressor and indoor fan is running, 
to turn the unit off, the compressor, outdoor fan will stop running. The upper and lower guide board 
rotate to horizontal position, then the indoor fan will run at low fan speed, 10s later, the unit will turn 

off. 

8

 

 

 

 

 

Summary of Contents for CH-S07LH/R2

Page 1: ...eep it for further reference OWNER S MANUAL MANUAL C H AIR CONDITIONERS Thank you for selecting H air conditioners Please read this manual carefully before operation and keep it for further reference...

Page 2: ...with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible...

Page 3: ...about 5 degree It can preclude the electricity wasted Don t leave windows and doors open for a long time while operating the air conditioner It can decrease the air conditioning capacity Don t block...

Page 4: ...ong time It can cause the health problems Don t use the air conditioner for other purposes such as drying clothes preserving foods etc Splashing water on the air conditioner can cause an electric shoc...

Page 5: ...capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high hu...

Page 6: ...he starting condition 2 In Heat mode the temperature arrive at the setting value and the compressor stop running about 1min The operating temperature range outdoor temperature for cooling unit is 21 4...

Page 7: ...out The pattern in displayer Cool Dry Heat Run Set temp Wireless remote control Air in Air out 5 Outdoor unit Indoor unit 1 Power cable 2 Remote control 3 Front panel 4 Filter 6 Wall pipe 5 Guide louv...

Page 8: ...pressing this key you may select AUTO FAN 1 FAN 2 FAN 3 or FAN 4 and may also cycle between them FAN 4 only in cool or heat mode After being energized AUTO is defaulted Only LOW fan can be set under D...

Page 9: ...o switch on the unit and cancel the auto switch on When the temperature display becomes constant you may press this key again to display the remaining set time The time value T On and H will display c...

Page 10: ...e running method and to make ambient comfortable About LOCK Under switch on or switch off state you may hold and key simultaneously to lock and unlock the keypad When locked the display will show the...

Page 11: ...ration should be in its receiving range It should be placed at where is 1m away from the TV set or stereo sound sets If the wireless remote control can not operate normally please take them out after...

Page 12: ...angle pull the air filter downward and take it out please see the Fig 4 a b a b Clean the air filter To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with war...

Page 13: ...hether the installation stand of the outdoor unit is damaged or not If damaged please contact the dealer Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Cle...

Page 14: ...the smell accumulated in the ambient Solution method Cleaning the filter If problem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow...

Page 15: ...nsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged...

Page 16: ...the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 2min In HEAT mode when the outdoor temperature is low or high humidity there are mu...

Reviews: