background image

5  

Installing Tank Ball Valve 

The RO storage tank comes with a 3/8” shut off valve that must be installed. 

 

1.  Apply 5-6 wraps of Teflon thread sealant tape to the male thread on the RO storage tank. 
2.  Install the shut-off valve and tighten until the gasket is compressed. 

 

NOTES: 
While there is a gasket that seals against the shut off valve, it is recommended to still use Teflon 

tape on the tank threads to insure a good seal is achieved.  It is also recommended to check for 

any leaks after the system has had time to produce water and pressurize inside the storage tank.  
Failure to do so could result in a leak that is not spotted until after the installer has left the loca-

tion.

 

Installing the Membrane 

When handling membranes be sure hands are clean and sanitized or wear surgical gloves. 
 

1. 

Remove the blue quick connect clip and pull the inlet tubing to the membrane cap out. 

2. 

Loosen and remove RO membrane cap using wrench provided. 

3. 

Using scissors or a knife, cut the end of the plastic wrapper from the membrane.  Leave it in the wrap-
per so you do not touch the membrane directly with your fingers. 

4. 

Insert the membrane all the way into the housing. 

5. 

Check that the o-ring is in place and install the cap onto the RO membrane housing.  Tighten   cap 
firmly by hand.  Using the wrench provided tighten an addition 1/4 to 1/2  turn. 

Summary of Contents for RO 75 GPD 4 STAGE BP

Page 1: ...COMMENDED TO WAIT UNTIL THE ENTIRE SYSTEM IS PRESSURIZED INCLUDING STORAGE TANK FAUCET AND RE CHECK FOR ANY LEAKS BEFORE LEAVING INSTALLATION SITE IT IS NORMAL FOR SOME BLACK CARBON FINES TO APPEAR IN...

Page 2: ...ms use four stages of treatment to filter your water Stage 1 Remove sand dirt sediment Stage 2 Remove chlorine taste odors very fine particulates Stage 3 Reduce total dissolved minerals Stage 4 Polish...

Page 3: ...em can be installed to provide the feed water for these features but you should consult your fridge owners manual for further information Guidelines for component placement are as follows Faucet shoul...

Page 4: ...ered water ready for use Faucet Standard used to dispense RO water when needed Optional air gap and designer faucets are available Post Carbon Filter is provided for a final polish to provide great ta...

Page 5: ...ank Failure to do so could result in a leak that is not spotted until after the installer has left the loca tion Installing the Membrane When handling membranes be sure hands are clean and sanitized o...

Page 6: ...oves eye protectors To make the faucet mounting hole if sprayer or second hole is not used check below to make sure the drill does not interfere with anything below the sink Center punch a small inden...

Page 7: ...f the floor Level it and mark the loca tion of mounting screws 2 Install the screws Leave 1 4 of the screw head out from the wall 3 Install the mounting bracket slots over the screws and hang the unit...

Page 8: ...nnect 3 8 tubing storage tank 4 Connect tubing to inlet water supply valve For air gap models connect 1 4 tubing to faucet and 3 8 tubing from faucet to drain saddle 5 Check all connections to be sure...

Page 9: ...aks 3 Allow system to process water for approximately 1 hour at which point tank will be practically full 4 Open faucet again and allow tank to empty for a second time It is normal to see some black c...

Page 10: ...bing into fitting 2 Defective tubing 2 Cut damage section of tubing and re install Not enough product water Pump not running Pump running but system not producing water Leaks Spare Parts List RO 75 GP...

Page 11: ...NE HOUSING PP 1 22 41203005 CONTROLLER 1 23 41323002 LARGE SINGLE CLAMP PP 2 24 41209004 SOLENOID VALVE 420ML MIN 1 25 41317002 CONTROL BOX pp 1 26 42005016 PRODUCT WATER CHECK VALVE 3 8 O D 3 8 O D 1...

Page 12: ...ce any part which fails two 2 years from date of manufacture as indicated by the serial number or date code provided the failure is due to a defect in material or workmanship The only exception shall...