24
25
1
3
2
4
1
3
2
4
Injector Configuration Upflow
Injector
Screen
3.
Press and hold
both button two (2)
and
button four (4)
at the same time to unlock the
Programming Screen
4.
Press button four (4)
to select Salt vs Efficiency
5.
Press
button three (3)
to go to
Line H
to change
Grains.
Press
button four (4)
arrow to change
2500 to 2100. Press
button three (3)
until
setting is complete. Press
button one (1)
to exit.
1
3
2
4
■
Language
■
Region
■
Valve
■
Meter Ratio
■
Salt vs Efficiency
=Salt vs Efficiency=
■
E 03.0 lbs Vs 5000Grs
■
S 06.0 lbs Vs 4150Grs
■
H 12.0 lbs Vs 2
1
00Grs
Size CF
Color
75
#1 WHITE
100
#1 WHITE
150
#1 WHITE
200
#2 BLUE
250
#2 BLUE
300
#3 YELLOW
IMPORTANT
The injector cage must be lined
up and inserted properly to
avoid crushing when the
injector cap is re-installed.
Markings on the cage and
valve body must line up.
Key Locked,
Press
[ ]
Key for 5S
to Unlock
1.
Press and hold
button one (1
), the display will read
“PRESS
[ ]
5 Seconds to Unlock”
.
2.
After 5 seconds, the display will beep confirming unlock.
MANDATORY
Programming changes are necessary to
compensate for the injector conversion.
CAUTION!
DO NOT over tighten
injectors. Snug tight only.
89UF Valve
Replace injectors with correct number and color corresponding
to your equipment size.
*NOTE
: Remember to properly lubricate ALL O Rings with
Silicone Lubricant - supplied.
Programming Change Required
Change the high capacity settings in the second level
programming from 2,500 grains per pound of salt to 2,100
grains per pound of salt.
PROBLEM WATER INJECTOR KIT
For use on upflow softeners only.
IMPORTANT!:
If the water source this water softener is being applied on is not municipal water
and contains up to 2.0 mg/l/ppm of ferrous (Clear Water) iron and/or up to .75 mg/l/ppm of manganese, the enclosed Problem Water Injector Kit
needs to be installed into the control valve following these instructions.
FAILURE TO DO THIS WILL RESULT IN UNSATISFACTORY OPERATION
OF THIS EQUIPMENT AND VOID ANY IMPLIED PERFORMANCE WARRANTY.