ALX SERIES

SPUN ALUMINUM EXHAUSTERS

ALX-M-07_31_14

Page 5 of 5

1

2

3

44

6

5

7

8

9

2

4

1

ALX SERIES SPUN ALUMINUM UPBLAST 

EXHAUSTERS - EXPLODED VIEW

Canarm Ltd. - Corporate Head Office    

2157 Parkedale Avenue, PO Box 367    Brockville, Ontario   Canada   K6V 5V6

Tel: (613) 342-5424;   Fax: (613) 342-8437

www.canarm.com                     [email protected]                 www.delhi-industries.com                                          

ITEM #

D

E

SCR

I

P

TI

O

N

QTY

1

T

O

C

AP

1

2

M

O

T

OR

 W

R

AP

1

3

M

O

T

OR

 

S

UPP

OR

T PLATE

1

4

VIB

R

ATI

O

N ELIMINAT

OR

4

5

T

O

P PLATE

1

6

UPBLA

S

T AP

RO

N

1

7

VENT

1

8

VE

R

TI

C

AL B

R

A

C

KET

4

9

INLET BAFFLE

4

1

0

DR

AIN

4

11

M

O

T

OR

 

S

UPP

OR

R

AIL

2

1

2

H

OR

IZ

O

NTAL B

R

A

C

KET

4

1

3

BA

S

E

1

14

BL

O

WE

R

 WHEEL 

1

5

6

7

3

2

8

9

4

14

11

12

10

13

ALX SERIES SPUN ALUMINUM DOWNBLAST

EXHAUSTERS - EXPLODED VIEW

ITEM #

D

E

SCR

I

P

TI

O

N

QTY

1

M

O

T

OR

 W

R

AP

1

2

BEA

R

ING

2

3

M

O

T

OR

 

S

UPP

OR

T PLATE

1

4

VE

R

TI

C

AL B

R

A

C

KET

4

5

T

O

C

AP

1

6

VENT TUBE

1

7

DO

WNBLA

S

T AP

RO

N

1

8

M

O

T

OR

 

S

UPP

OR

R

AIL

2

9

VIB

R

ATI

O

N ELIMINAT

OR

4

1

0

S

HAFT

1

11

T

O

P PLATE

1

1

2

INLET BAFFLE

1

1

3

BA

S

E

1

14

BL

O

WE

R

 WHEEL

1

HVAC  PRODUC S

HVAC PRODUC S

 

HVAC PRODUC S

NOTE:  General models are shown above.  Actual unit might vary according to size.

Summary of Contents for ALX SERIES

Page 1: ...CEIVER MUST NOTE ANY DAMAGE ON THE CARRIER S BILL OF LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS...

Page 2: ...nd on the control box itself 4 Motor RPM range would be from full RPM to the RPM just set The lowest minimum voltage that may be applied to the motors is 65VAC Running at lower voltage can cause prema...

Page 3: ...sconnect switches are available for purchase as accessories No dampers can be used in the system UL762 RESTAURANT EXHAUST APPLICATION 1 Lock out all power sources 2 Inspect all fasteners and set screw...

Page 4: ...ong wheel rotation Re wire the motor to change direction of rotation Improper Duct System Check obstruction of duct in the duct or dirty filter Fan does not operate Reduced airflow Excessive noise vib...

Page 5: ...IBRATION ELIMINATOR 4 5 TOP PLATE 1 6 UPBLAST APRON 1 7 VENT 1 8 VERTICAL BRACKET 4 9 INLET BAFFLE 4 10 DRAIN 4 11 MOTOR SUPPORT RAIL 2 12 HORIZONTAL BRACKET 4 13 BASE 1 14 BLOWER WHEEL 1 5 6 7 3 2 8...

Page 6: ...a aucun dommage SI VOUS CONSTATEZ DES DOMMAGES VOUS DEVEZ LES NOTER SUR LE CONNAISSEMENT DU TRANSPORTEUR ET FAIRE UNE R CLAMATION AU TRANSPORTEUR IMM DIATEMENT NE SOULEVEZ PAS L QUIPEMENT PAR LE CAPOT...

Page 7: ...est 65VAC Un voltage en de de ce niveau peut causer un d faillance pr matur e du moteur Pour un moteur 3 phases un entra nement fr quence varaible VFD est requis pour ajuster la vitesse du moteur CON...

Page 8: ...alignement et la tension si applicable 4 Con rmer que le voltage utilis est identique celui du moteur et que le tout est bien c bl 5 Faire la rotation de la roue pour s assurer que ni la pale ni la c...

Page 9: ...et v rifier l op ration du volet contr l Mauvaise rotation de la roue Refaire le c blage pour changer la direction de la rotation Syst me de conduit inad quat Redimensionner le conduit Bruit vibration...

Page 10: ...D BIT VERS LE HAUT 1 7 VENT 1 8 FERRURE VERTICALE 4 9 D FLECTEUR D ENTR E 4 10 DRAIN 4 11 RAIL DE SOUTIEN DU MOTEUR 2 12 FERRURE HORIZONTALE 4 13 BASE 1 14 ROUE DE VENTILATEUR 1 5 6 7 3 2 8 9 4 14 11...

Reviews: