Page 2 of 5

1.

A qualified electrician in accordance with all local and National Electrical Codes should do all wiring. 

2.

Ensure power supply is disconnected and locked out prior to making electrical connections.  

3.

Wire the motor according to the wiring diagram on motor label or on the sticker inside the motor wrap. All motors should be wired to
the same rotation as indicated on the sticker on the top plate. 

4.

Leave enough slack in the wiring to allow for motor movement when adjusting the belt tension.  

5.

Excess wire must be restrained in order to prevent it from entering the pulley, shaft or wheel rotating area.  

6.

Disconnect switches are recommended and should be located near the fan in order to, swiftly cut off power in case of an emergency
and maintain complete control of the power source.

Some single phase direct drive motor’s running RPM can be adjustable with a variable speed control (please contact factory for more 
information). The speed control knob starts at off position, then high to low adjust range. At high speed, the speed control would allow the
motor running at its maximum RPM. Dial the knob to the low side would let the speed control regulate the voltage on the motor to reduce
the RPM.
A minimum speed adjustment is needed to limit the motor RPM range. Follow this procedure to set the minimum speed.

1.

Motor must be in servicing status to allow the minimum speed setting. Motor would not slow down unless proper load is applied. 
Motor RPM would be changed under different system (static pressure).

2.

Turn the main control knob to the lowest speed position.

3.

Locate and adjust the minimum speed setting, it can be found on the control box itself.

4.

Motor RPM range would be from full RPM to the RPM just set. 

The lowest minimum voltage that may be applied to the motors is 65VAC. Running at lower voltage can cause premature failure
to the motor.

For 3 phase motors, a variable frequency drive (VFD) is required to adjust motor speed.

VARIABLE SPEED CONTROL – SINGLE PHASE

VARIABLE FREQUENCY DRIVE – THREE PHASE

1.

Install roof curb, caulk and flash to ensure the water tightness.

2.

Rotate the blower wheel by hand. Wheel should not be rubbing against the housing inlet. If rubbing occurs, loosen the set screws on
the wheel hub and shift the wheel to obtain clearance. Then re-tighten all set screws.

3.

Complete all subsequent duct connections.

4.

Secure the fan to the curb cap. Do not lift the unit by the hood or motor. Lift the unit by horizontal supports on direct drive or by motor

mounting plate for belt drive unit.

5.

Use at least 8 proper fasteners to connect the blower base to the roof curb.

6.

Verify if the power supply is compatible with the equipment. 

7.

Make sure the power line is shut down before wiring the motor to power line.

8.

Remove top cap, connect power line to the motor/disconnect switch as indicated.

9.

For all up blast units, the electrical supply enters the motor compartment through the vent tube.

10.

Ensure all fasteners and set screws are tightened.

11.

Place the top cap back on the hood.

12.

Caulk and flash the fan base and roof curb to ensure good water tightness.

INSTALLATION

R

E

CO

MMEN

D

E

D

ROO

O

PENIN

G

WI

R

E

D

 T

O

 P

O

WE

R

B

O

THE

R

S

ROO

F

D

E

C

K

O

PTI

O

NAL 

D

IS

CO

NNE

C

C

AN 

B

E M

OU

NTE

D

 INSI

D

E THE 

H

OU

SIN

G

 

OR

 

OU

TSI

D

E

MINIM

U

12

R

E

CO

MMEN

D

E

D

ROO

O

PENIN

G

ROO

F

D

E

C

K

MINIM

U

12

WI

R

O

PTI

O

2

:

WI

R

E TH

ROUG

H

THE VENT T

UB

E

WI

R

O

PTI

O

1

:

TH

ROUG

CO

N

DU

IT

GENERAL CLEAN AIR APPLICATION (UP BLAST)

GENERAL CLEAN AIR APPLICATION, DOWN BLAST

Note: ALX105 and ALX120 has only wiring option 1, ALX210 and larger has
only wiring option 2 available. 

STANDARD WIRING INSTRUCTIONS

Summary of Contents for ALX SERIES

Page 1: ...CEIVER MUST NOTE ANY DAMAGE ON THE CARRIER S BILL OF LADING AND FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY DO NOT LIFT THE UNIT BY THE HOOD OR MOTOR PLEASE LIFT THE UNIT BY HORIZONTAL SUPPORTS...

Page 2: ...nd on the control box itself 4 Motor RPM range would be from full RPM to the RPM just set The lowest minimum voltage that may be applied to the motors is 65VAC Running at lower voltage can cause prema...

Page 3: ...sconnect switches are available for purchase as accessories No dampers can be used in the system UL762 RESTAURANT EXHAUST APPLICATION 1 Lock out all power sources 2 Inspect all fasteners and set screw...

Page 4: ...ong wheel rotation Re wire the motor to change direction of rotation Improper Duct System Check obstruction of duct in the duct or dirty filter Fan does not operate Reduced airflow Excessive noise vib...

Page 5: ...IBRATION ELIMINATOR 4 5 TOP PLATE 1 6 UPBLAST APRON 1 7 VENT 1 8 VERTICAL BRACKET 4 9 INLET BAFFLE 4 10 DRAIN 4 11 MOTOR SUPPORT RAIL 2 12 HORIZONTAL BRACKET 4 13 BASE 1 14 BLOWER WHEEL 1 5 6 7 3 2 8...

Page 6: ...a aucun dommage SI VOUS CONSTATEZ DES DOMMAGES VOUS DEVEZ LES NOTER SUR LE CONNAISSEMENT DU TRANSPORTEUR ET FAIRE UNE R CLAMATION AU TRANSPORTEUR IMM DIATEMENT NE SOULEVEZ PAS L QUIPEMENT PAR LE CAPOT...

Page 7: ...est 65VAC Un voltage en de de ce niveau peut causer un d faillance pr matur e du moteur Pour un moteur 3 phases un entra nement fr quence varaible VFD est requis pour ajuster la vitesse du moteur CON...

Page 8: ...alignement et la tension si applicable 4 Con rmer que le voltage utilis est identique celui du moteur et que le tout est bien c bl 5 Faire la rotation de la roue pour s assurer que ni la pale ni la c...

Page 9: ...et v rifier l op ration du volet contr l Mauvaise rotation de la roue Refaire le c blage pour changer la direction de la rotation Syst me de conduit inad quat Redimensionner le conduit Bruit vibration...

Page 10: ...D BIT VERS LE HAUT 1 7 VENT 1 8 FERRURE VERTICALE 4 9 D FLECTEUR D ENTR E 4 10 DRAIN 4 11 RAIL DE SOUTIEN DU MOTEUR 2 12 FERRURE HORIZONTALE 4 13 BASE 1 14 ROUE DE VENTILATEUR 1 5 6 7 3 2 8 9 4 14 11...

Reviews: