background image

A2X SERIES

 

 

SPUN ALUMINUM EXHAUSTERS

M-A2X _05_13_22

Page 5 of 5

FAN TROUBLESHOOTING

PROBLEM

POSSIBLE ISSUE

SOLUTION

Wheel rubbing inlet

Adjust wheel, loosen set screw(s) and move the wheel, acquiring 
clearance between inlet and wheel, then re-tighten set screw(s)

Wheel unbalance

Check wheels for debris or dirt build up and clean when necessary

Object in rotation area or housing

Remove object

Motor compartment loose

Re-tighten the fasteners

Malfunction of electrical supply

Check supply voltage, fuse and switch

Malfunction of motor

Check wiring and overload protector

Motor overload/overheat

Wrong wheel rotation

Re-wire the motor to change direction of rotation

Damper Malfunction

Check opening side of back draft damper, check operation status of 
controlled damper

Wrong wheel rotation

Re-wire the motor to change direction of rotation

Improper Duct System

Check obstruction of duct in the duct or dirty filter

Discharge Blockage

Check discharge and remove any debris

Excessive noise/vibration

Fan does not operate

Reduced airflow

WARNING

 

MA

k

E SURE THE UNIT IS NOT CAPABLE OF OPERATION DURING REPARATION.

Canarm Ltd. - Corporate Head Office    

2157 Parkedale Avenue, PO Box 367    Brockville, Ontario   Canada   K6V 5V6 

Tel: (613) 342-5424;   Fax: (613) 342-8437            

www.canarm.com                     [email protected]                                                     

WARRANTY

CANARM Ltd.

 warrants every new fan to be free of defects in material and workmanship to the extent that, within a period of one year 

from the date of purchase 

CANARM Ltd.

 shall either repair or replace at 

CANARM

’s option, any unit or part thereof, returned freight 

prepaid, and found to be defective. 

 

This warranty does not include any labour or transportation costs incidental to the removal and reinstallation of the unit at the user’s  

premises. 

 

Components repaired or replaced are warranted through the remainder of the original warranty period only; it is null and void in case of  

alteration, accident, abuse, neglect, and operation not in accordance with instructions. 

 

NOTICE: 

No warranty claims will be honored by 

CANARM Ltd.

 unless prior authorization is obtained. 

Disconnect and secure to the OFF position all electrical power to the fan prior to inspection or servicing. Failure to comply with this safety 

precaution could result in serious injury or death.

 

 
1.

  Ventilator should be checked at least once a year. For critical or severe applications a routine check every two to three months is  

suggested. 

2.

Guard to be kept free of debris. Easily installed/removed using the integrated twist lock tabs. Gently twist the guard tab so that it slips 
under the support arm to lock in place. Guard is easily removeable for fan servicing and cleaning. No tools are required. 

3.

When moving or installing a belt, don’t force the belt over the sheave. Loosen the motor mount so that the belt can be easily slipped 
over the sheave. 

4.

The belt, on belt driven units, should be removed and carefully checked for cracks, ply separation or irregular wear. A small 
irregularity in the contact surface of the belt will result in noisy operation. If any of these defects are apparent the belt should  
be replaced. At the same time check the sheaves for chips, dents or rough surfaces that could damage the belt. 

5

. The correct belt tension is important. Too tight a belt will result in excess bearing pressure, which can cause premature bearing failure 

and may cause the motor to overload.  Too loose a belt will result in slippage, which will burn out belts. Proper belt deflection should 
be 1/64” (half way between sheave centers) for each inch of belt span when a force of approximately 5 lbs. is applied. 

MAINTENANCE 

6.

The belt alignment should be checked to be sure that the belt is running perpendicular to the rotating shafts. Motor and drive shafts 
must be parallel. 

7.

A periodic inspection of all fasteners should be carried out to ensure they have not loosened due to vibration. Particular attention 
should be paid to fasteners attaching the wheel to the shaft and those attaching the shaft to the bearing.

Summary of Contents for A2X Series

Page 1: ...provincial and local codes all of them will supersede this manual 9 Failure to follow the safety instructions in this manual may cause serious injury or death due to electrical shock or high speed ro...

Page 2: ...RPM range would be from full RPM to the RPM just set The lowest minimum voltage that may be applied to the motors is 65VAC Running at lower voltage can cause premature failure to the motor For 3 phase...

Page 3: ...del The control module features a 4 digit LED display that indicates demand of full speed and motor speed in rpm The display also indicates an error code message for minor diagnostics if required Moto...

Page 4: ...itches are available for purchase as accessories No dampers can be used in the system RESTAURANT EXHAUST APPLICATION 1 Lock out all power sources 2 Inspect all fasteners and set screws and tighten as...

Page 5: ...accident abuse neglect and operation not in accordance with instructions NOTICE No warranty claims will be honored by CANARM Ltd unless prior authorization is obtained Disconnect and secure to the OF...

Page 6: ...concernant l usage de cet appareil car ils supplantent de manuel 9 Ne pas suivre les instructions de ce manuel peut causer de s rieuses blessures ou la mort due un choque lectrique ou aux pi ces en ro...

Page 7: ...de ce niveau peut causer un d faillance pr matur e du moteur Pour un moteur 3 phases un entra nement fr quence variable VFD est requis pour ajuster la vitesse du moteur CONTR LE DE VITESSE VARIABLE U...

Page 8: ...si n cessaire La vitesse du moteur peut tre chang e en ajustant le pot de contr le de la vitesse situ sur le module de contr le Un petit tournevis peut tre utilis pour faire cet ajustement M A2X FR_05...

Page 9: ...OUVERTURE DU TOIT RECOMMAND E CONDUIT SOUD PAR AUTRUI CONDUIT SOUD PAR AUTRUI REBORD VENTIL MINIMUM DE 20 DE LA CIME DU TOIT C BL POUR TRE ALIMENT PAR D AUTRES MUR SURFACE DU TOIT INTERRUPTEUR DE FER...

Page 10: ...ration excessif D bit d air r duit Mettre l appareil hors tension et fermer le disjoncteur avant de faire l inspection ou l entretien Un manque cette directive pourrait causer de s rieuses blessures o...