4. Comm. & Monitoring
4. Comm. & Monitoring
f. Please insert terminal board into terminal block, then will be clamped automatically.
c. Insert the cable through the cap nut for each port. COM2(RS485 IN) COM3(RS485 OUT).
d. Pull down the terminal block on user interface board(See Figure 4.5).
e. Firstly insert cable into terminal board, then tighten the screws (dotted area) clockwise
with slotted screwdriver; if user need to pull out cable, screws rotates anticlockwise with
slotted screwdriver(See Figure 4.5).
4.2 Ethernet communication
≈
Inverter 1
Inverter 2
Inverter n
Ethernet IN | OUT
Ethernet
Router
Internet
Ethernet IN | OUT
Ethernet IN | OUT
Figure 4.7
Use the RJ45 connectors to perform the Ethernet communication which supports the
Canadian Solar Monitoring Platform and Modbus TCP protocol(Both By Default).
NOTE:
When creating daisy chain for Ethernet communication,
all inverters' slave
address must be set to 01.
CAT 5E outdoor rated (cable outer diameter<9mm, internal resistance≤1.5Ω/10m) and
shielded RJ45 connectors are recommended.
If the product is connected to a local network through a router, the product will be assigned
an IP address automatically, by the DHCP server.
Daisy chain is required for multiple inverter communication through ethernet as shown below.
Address: 01
Address: 01
Address: 01
NOTE:
Laptop is required for onsite Ethernet communication commissioning.
If the router doesn't support automatic IP address, use an Ethernet cable to
connect the module and your laptop.
Change the Laptop's IP address as
10.10.100.253 and then Use the web browser to enter 10.10.100.254 and
define your own IP address as in Figure 4.8.
Recommended web browser: Internet Explorer or Chrome.
2. RS-485 communication through terminal board.
Figure 4.4
1
2
4
3
The cross sectional area of the cable wire for terminal board connection should be 0.2-1.5mm.
The outer diameter of the cable may be 5mm-10mm.
NO
.
Port definition
Description
1
2
3
4
RS485A1,RS485 differential
RS485B1,RS485 differential signal-
RS485A2,RS485 differential
RS485B2,RS485 differential signal-
RS485A1 IN
RS485B1 IN
RS485A2 OUT
RS485B2 OUT
Connection
of
Terminal
board.
a. Strip the insulation and shield to a suitable length. Use diagram below as a guide.
(in Figure 4.5).
b.
Remove the cap nut from the waterproof cable glands labeled at the bottom of the inverter.
Remove the plug from the fitting. (in Figure 4.6).
8mm
30mm
Figure 4.5
Figure 4.6
System
Work
mode
Network
Manual
Restart
Reset
Upgrade
Work
mode
settings
Work
mode
Protocol type
IP
address
of
the
device
Port
of
the
device
Local
+
Remote
ModBus
TCP
192
.
168
.
3
.
50
30003
Save
Figure 4.8 (Example Only)