EN-Rev IM/GN-AM-EN/1.4 Copyright © July, 2018. Canadian Solar Inc.
12 |
table 3-1: approved bolting methods
Bolting on short frame side using four standard
mounting holes. Mounting rails run parallel to the
long frame side.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 2400 Pa
≤
Compatible module types: CS6A-P, CS6A-M and
CS6A-MS
Bolting on short frame side using four standard
mounting holes. Mounting rails run perpendicularly to
the long frame side. An additional support bar should
be placed below the module as shown below.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Compatible module types: CS6A-P, CS6A-M and
CS6A-MS
Bolting on long frame side using four innermost
mounting holes. Mounting rails run perpendicularly to
the long frame side.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Compatible module types: CS1V-MS, CS1K-MS, CS3K-P,
CS3K-MS, CS6A-P, CS6A-M, CS6V-P, CS6V-M, CS6K-P,
CS6K-M, CS6K-MS, CS6V-MS, CS6VL-MS and CS6A-MS
Bolting on long frame side using four innermost
mounting holes. Mounting rails run parallel to the
long frame side.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 4000 Pa
≤
Compatible module types: CS1V-MS, CS1K-MS,
CS3K-P, CS3K-MS, CS6A-P, CS6A-M, CS6A-MS, CS6V-P,
CS6V-M, CS6V-MS, CS6K-P, CS6K-M, CS6K-MS
Bolting on long frame side using four middle
mounting holes. Mounting rails run perpendicularly
to the long frame side.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Compatible module types: CS3U-P, CS3U-MS,
CS6U-P, CS6U-M and CS3W-P
Support bar
Bolting on long frame side using four middle
mounting holes. Mounting rails run parallel to the
long frame side.
Maximum Load:
Uplift load 2400 Pa
≤
Downforce load 5400 Pa
≤
Compatible module types: CS3U-P, CS3U-MS,
CS6U-P and CS6U-M