48
ENGLISH
BUILT-IN GAS HOB WITH GLASS LID
▪
FC1346 series
GAS CONNECTION
CAUTION!
Before setting up the connection, make sure that the gas system and the installation rooms are
suitable for the purpose and comply with the standards in force in the Country of installation.
Refer to the specific technical standards regarding conformity of gas systems (LPG) for the
household (UNI CIG 7131 and 7129), nautical ( UNI EN ISO 10239) and recreational vehicles
(UNI EN 1949) sectors.
Before connecting the gas, also check that:
▪
the supply line is free from obstructions and has a sufficient flow rate to guarantee correct operation
of the appliance;
▪
there is a suitable pressure regulator/reducer compliant with the gas categories used on the appliance
immediately downstream of the gas cylinder or container feeding the system;
▪
• a gas shut-off valve or a valve disconnecting the system is installed on the supply line, downstream
of the connection flange to the cooking device, in a place which can easily be accessed and inspected
(
Please note:
this valve must always be shut during installation and maintenance on the appliance).
CAUTION!
Make sure that the type of gas feeding the appliance is among those allowed and listed in the
instruction booklet (see paragraph “Gas categories”).
CAN S.r.l. declines any liability for incorrect connections, not carried out in a workmanlike manner or
performed by non-professionally qualified individuals.
GAS CATEGORIES
The appliance was designed for correct operation only with the types of gas categories and operating
pressures listed below:
gas
categories
and
countries
of
use
in
accordance
with
en
30-1-1: 2008
+
a3:2013
gas
category
and
country
of
destination
name
of
gas
operating
pressure
I3B/P (30)
AL-CY-GR-LT-MK-PT-SI-TR
AT-BG-HR-DK-EE-FI-DE-IS-LV-MT-NO-
NL-RO-SK-SE-HU
Butane (G30)
Propane (G31)
30 mbar
30 mbar
I3+ (28-30/37)
AL-CY-GR-LT-MK-PT-SI-TR
BE-FR-IE-IT-GB-CZ-SK-ES-CH
Butane (G30)
Propane (G31)
28 - 30 mbar
37 mbar
CONNECTION PIPE REQUIREMENTS
CAUTION!
The appliance must be connected to the gas pipeline by means of a suitable connection pipe
making use of certified sealed fittings of the most suitable type for the application.
The last section of the gas supply line to the device may also be made with suitable flexible connection
pipes (pay attention to the types allowed by the regulations on the construction of on board devices). If
flexible hoses are used, they must:
▪
always be able to be inspected,
▪
be protected against contact with hot parts of the hob or other electrical appliances in the immediate
vicinity (e.g. cups, burners, bottom and sides of the hob, gas unit, etc...),
▪
be protected against the movable parts of the recessing (drawers, doors, etc.),
▪
have a length which complies with the technical standards for each sector of reference.