Section 06 ELECTRICAL SYSTEM
Subsection 03 (STARTING SYSTEM)
PROCEDURES
STARTER SOLENOID
Solenoid Continuity Test
Remove the 20 A main fuse and the 20 A charging
system fuse for circuit isolation.
vmr2008-026-001_b
PF2 FUSE HOLDER
1. Main fuse
2. Spare fuse
3. Charging system fuse
Disconnect and remove the battery, refer to the
CHARGING SYSTEM
section.
Remove the solenoid mounting screw.
vmr2008-026-005_a
Disconnect the small terminal wires from the so-
lenoid.
vmr2008-026-007_a
1. Small solenoid coil wires
2. Small solenoid coil terminals
Set multimeter to
.
Measure solenoid coil resistance as follows.
CAUTION: Battery must remain disconnected
for the following continuity tests or multimeter
damage may occur.
vmr2008-026-008_a
SOLENOID COIL CONTINUITY TEST
MEASUREMENT
SOLENOID POSTS
RESISTANCE
@ 20°C (68°F)
SS1
SS2
Approx. 7
Test for a stuck solenoid plunger by measuring
the resistance across the solenoid contacts as fol-
lows.