HSEUREG04801(R2) MANUAL

Temperature Derating

 

The maximum ambient temperature during operation is + 70°C. If the over 
temperature protection is activated, the power supply is switched off. 

The measuring point is 50mm outside the power supply. The power supply 
unit starts automatically when it has cooled down. 

Series Operation

 

Two or more units of the same model and output voltage can be operated up to a total voltage of 240Vdc in 
series. Due to the dielectric strength of the internal components used, only the models with an output voltage of 
90Vdc and later are approved for series operation. Other power supplies are not approved for series operation 
above 60Vdc. 
If the units are remotely controlled via the analogue interface it is compulsory to use a potential-free control 
voltage! 

Parallel Operation & N+1 Decoupling

 

To increase the overall power of the power supply, two or more devices of 
the same model with the same output voltage may be operated in parallel. 
We recommend using a busbar for the DC power connector. Make sure 
that the cable lengths and cable cross-sections of all power supplies to the 
busbar or to the star point are identical. Allow proper connection for low 
contact resistance. If you want to use the sensing function, connect it also 
to the star point or busbar. To avoid measurement errors, select the line 
length from the neutral point or from the busbar to the load as short as 
possible and use the maximum possible conductor cross-section. 

The HSEUREG models have no internal O-ring diode, to operate the 
devices N+1 redundant. 

Coating Option

 

We offer the HSEUREG-series with optional coating. It is to be used in e.g., dusty, dirty, high humidity, or in 
awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be 
prevented. The coat itself is a transparent acrylic resin. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, 
IPC-CC-830B, UL listed as permanent coating File No.: E80315 , UL94V-0 

Electrical Safety (Factory-Test / Field-Test Owner)

 

 
 
 

  
¹) 

90Vdc= 2000Vdc 

Type and factory test are the manufacturer. While repeating damage can 
happen to the power supply unit. For the field test (owner) follow the below instruction:

 

a)

Use suitable test equipment, raising the voltage slowly

b)

Short circuit L1 and N, and all the DC output terminals.

c)

Use only test voltages of 50/60Hz. The outputs are unearthed and
therefore they have no resistance to GND/PE.

d)

If the residual voltage is 

60Vdc, observe the safety standards.

Use only specially insulated screwdriver to trim the Ua/Ia.

C

1

)

 

Type Test 

60s 

2500Vac 

3000Vac 

500Vdc 

Factory Test 

5s 

2000Vac 

2000Vac 

500Vdc 

Field Test 

2s 

2000Vac 

2000Vac 

500Vdc 

Cut-off current setting  >15mA

>15mA

>1mA

[email protected]

www.powersolve.co.uk

020321

Summary of Contents for Powersolve HSEUREG04801 Series

Page 1: ...or long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010...

Page 2: ...t quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical device...

Page 3: ...cy for 0 Umax programming Startup Delay Typ 250ms Softstart Typ 100ms Startup from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit P...

Page 4: ...mote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output vol...

Page 5: ...he sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a batter...

Page 6: ...point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Page 7: ...f the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system whil...

Page 8: ...DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then...

Page 9: ...tripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Page 10: ...persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac and for 115Vac It is prohibited to use the unit without PE...

Reviews: