HSEUREG04801(R2) MANUAL

Manual und Technical Details 

Programming Time Vout [ms] 

Model

 

0-15V

0-30V

0-50V

0-90V

0-130V

0-180V

Rise Time 0-100%, 10/100% Last, [ms] typ. 

15/15 

15/15 

15/15 

15/15 

15/15 

15/15 

Slew Rate 90-10%, 10/100% Last, [ms] typ. 

48/4.8 

155/15.5 

74/7.4 

86/8.6 

78/7.8 

149/14.9 

Output Capacity, [mF] typ. 

10.36 

10,36 

1.85 

0.64 

0.28 

0.28 

Interface Latency 

15ms including signal latency for 0-Vmax programming 

Analog Interface

 

Pin 

Name 

Type 

Function 

Signal 

Remarks 

Ureg + 

Input 

Voltage Programming 

0-10Vdc/20mA & 0-20mA
multi-functional interface

500 

Ω

 working resistance with voltage 

programming 

Ureg - 

Input 

Sense + 

Input 

Sense Control 

none 

Compensation max. 2V per load line 

Sense - 

Input 

 

Input

 

External Shutdown Remote 
ON/OFF 

Open Collector or Switch 

Voltage drop <1V with typical 2.3mA 

Remote - 

Input

 

Programming Interface Ureg

 

The standard programming of the HSEUREG Series is an analogue 
interface. The output voltage is linearly proportional to the adjusted analogue 
control signal. If the control signal 0V applies the power supply delivers 0V at 
the output. The power supply is already working from 0V output voltage and 
low load with high precision. 

The analogue inputs are non-floating. The mass is connected to the DC 
negative output. The burden of the interface is 500

Ω

. 0-10V programming 

requires 20mA current. The latency to full compensation of V/C on the 
interface from 0-100% is typically 15ms for all HSEUREG models. 








E
R

F
I
L
T
E

C
O
N
T
R
O

C

1 = transient filter 
2 = rectifier 
3 = inrush limiter NTC 
4 = load capacitor 
5 = transformer 
6 = storage choke 

[email protected]

www.powersolve.co.uk

020321

Summary of Contents for Powersolve HSEUREG04801 Series

Page 1: ...or long life under full stress Strong input filters High reliability shock vibration proof Over Voltage and continuous short circuit protection EMI EMS EN61000 6 2 3 EN55032 class B EN61010 1 EN61010...

Page 2: ...t quality and most reliable devices in the world market Design Conception The HSEUREG power supply series realizes high programmable power in a space saving housing Latest generation electrical device...

Page 3: ...cy for 0 Umax programming Startup Delay Typ 250ms Softstart Typ 100ms Startup from Shutdown Typ 250ms Response Load Change 1ms 10 100 100 10 Base Load None Efficiency 230Vac 90 typical Short Circuit P...

Page 4: ...mote ON OFF Open Collector or Switch Voltage drop 1V with typical 2 3mA 6 Remote Input Programming Interface Ureg The standard programming of the HSEUREG Series is an analogue interface The output vol...

Page 5: ...he sense block has only connections We recommend twisted sense lines Local Sensing Remote Sensing Compensation of Load Line Drop Voltage Sense battery charger operation mode Remote Sensing as a batter...

Page 6: ...point or busbar To avoid measurement errors select the line length from the neutral point or from the busbar to the load as short as possible and use the maximum possible conductor cross section The H...

Page 7: ...f the main energy losses The internal coolers of the output diodes and the power FETs connect to the back plate cooler It is possible to dissipate about 40 50 of the energy losses out of a system whil...

Page 8: ...DIN Rail bracket according to EN60715 It is easy to mount dismount while snaping it onto the 35mm DIN Rail no tools necessary It is not allowed to install the HSEUREG in other mounting direction then...

Page 9: ...tripping Length 0 25mm H0 25 5 5mm H0 25 10 HBL 8mm 0 5mm H0 5 6 6mm H0 5 12 OR 8mm 1 0mm H1 0 6 6mm H1 0 12 GE 8mm 2 5mm H2 5 12 12mm H2 5 19D BL 14mm 4 0mm H4 0 12 12mm H4 0 20 GDR 14mm 6 0mm H6 0 2...

Page 10: ...persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of C Type 16A for 230Vac and for 115Vac It is prohibited to use the unit without PE...

Reviews: