HSEUiREG04801(R2) MANUAL
Camtec Power Supplies GmbH - Gewerbestrasse 30 - DE-76327 Pfinztal / Germany
P.14/15 (03/2017.02.2)
Tel. +49 (721) 46596 - 0 Fax +49 (721) 46596 - 77
www.camtec-gmbh.com
-
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
Connections
Clamping Yoke Connector Specifications
Input / Output connections
Signal connections plugs
Tightening torque min. – max.
1,2 – 2,2Nm (blade 1,0x5,5 DIN5264 )
0,2 – 0,25Nm (blade 0,4x2,2 DIN5264)
Touch-safe protection acc. to DIN VDE 0470
IP20 plugged/ IP10 unplugged
Not applicable
Clamping range, min. – max.
0,5 – 16mm² / AWG26 – AWG6
0,2 – 1,5mm² / AWG28 – AWG14
Solid, H05(07) V-U min. – max.
0,5 – 16mm²
0,2 – 1,5mm²
Stranded, H05(07) V-U min. – max.
6 – 16mm²
0,2 – 1,5mm²
Flexible, H05(07) V-U min. – max.
0,5 – 16mm²
0,2 – 1,5mm²
w. plastic collar ferrule, DIN 46228 pt 4 min. – max.
2,5 – 10mm²
0,2 – 1,5mm²
w. wire end ferrule, DIN 46228 pt 1, min. – max.
2,5 – 10mm²
0,2 – 1,5mm²
Plug gauge in accordance with EN 60999 a x b; ø
5,4 x 5,1mm; 5,3mm
2,4 x 1,5mm; 2,3mm
Pitch (P)
10,16mm
3,5mm
Wire Stripping Length (fine wired)
Nominal Cross Section
Wire End Ferrule
Stripping Length
Wire End Ferrule
Stripping Length
0,25mm²
H0,25/5
5mm
H0,25/10 HBL
8mm
0,5mm²
H0,5/6
6mm
H0,5/12 OR
8mm
1,0mm²
H1,0/6
6mm
H1,0/12 GE
8mm
2,5mm²
H2,5/12
12mm
H2,5/19D BL
14mm
4,0mm²
H4,0/12
12mm
H4,0/20 GDR
14mm
6,0mm²
H6,0/20
12mm
H6,0/20 SW
14mm
10,0mm²
H10,0/12
12mm
H10,0/22 EB
15mm
The length of ferrules is to be chosen depending on the rated voltage. The outside diameter of the plastic collar should not be larger than
the pitch (P)
Ordering Information
Ordering Codes
Product Code
Information
Article Number
HSEUiREG04801.018(R2)
0-18Vdc
3041083001CA
HSEUiREG04801.030(R2)
0-30Vdc
3041083002CA
HSEUiREG04801.050(R2)
0-50Vdc
3041083003CA
HSEUiREG04801.090(R2)
0-90Vdc
3041083004CA
HSEUiREG04801.130(R2)
0-130Vdc
3041083005CA
HSEUiREG04801.180(R2)
0-180Vdc
3041083006CA
HSEUiREG04801.240(R2)
0-240Vdc
3041083007CA
HSEUiREG04801.018PS(R2) PowerSink / Quick Downward Programming
3041083011CA
HSEUiREG04801.030PS(R2) PowerSink / Quick Downward Programming
3041083012CA
HSEUiREG04801.050PS(R2) PowerSink / Quick Downward Programming
3041083013CA
HSEUiREG04801.090PS(R2) PowerSink / Quick Downward Programming
3041083014CA
HSEUiREG04801.130PS(R2) PowerSink / Quick Downward Programming
3041083015CA
HSEUiREG04801.180PS(R2)
PowerSink / Quick Downward Programming
3041083016CA
HSEUiREG04801.240PS(R2)
PowerSink / Quick Downward Programming
3041083017CA
Certificate Calibration
Separate works certificate manufacturer calibration
-
Back Plate Kit
Hart mount plate kit including screws
2201002001CA
UI.DRIVE INTERFACE
USB2.0 Interface & software download
3041093001CA