Available Options 

 

Test Certificate and Calibration 

Optionally we offer with the delivery of a CPS power supply a Manufacturer's Inspection Certificate of electrical 
setpoint / actual values. The power supply then is "calibrated". Such Manufacturers Calibration Certificate for 
each power supply can uniquely be assigned via the device serial number. 
A manufacturer calibration of a CPS can frequently be done via controlled recirculation on a regular basis. 
Please request the help of your local CPS dealer or contact us directly:  [email protected]

 

 
 
 

Ordering Codes 

Product Code 

Information 

Article Number 

CPS-EX2000.024(R2) 

24Vdc model incl. analogue interface 

3041110002CA 

CPS-EX2000.036(R2) 

36Vdc model incl. analogue interface 

3041110003CA 

CPS-EX2000.048(R2) 

48Vdc model incl. analogue interface 

3041110004CA 

CPS-EX2000.072(R2) 

72Vdc model incl. analogue interface  

3041110005CA 

CPS-EX2000.110(R2) 

110Vdc model incl. analogue interface 

3041110006CA 

Certifcate Calibration 

Separate works certificate for manufacturer calibration of the power supply 

4031107001CA 

19“ Frontplate 2U 

Including mounting material

 

2201006001CA 

19“ Frontplate 3U 

Including mounting material

 

2201007001CA 

19“ Blindplate 2U 

Including mounting material

 

2201009001CA 

19“ Blindplate 3U 

Including mounting material

 

2201010001CA 

19“ Subrack 2U 

3 Modules mountable only in conjunction with front panel 2U orderable 

2201004001CA 

19“ Subrack 3U 

5 Modules mountable only in conjunction with front panel 3U orderable 

2201005001CA 

19“ Rack-Rail 

2x Support Rails for rack mount, mounting kit included 

2201008001CA 

Hard Mount Holder narrow 

2x Holder for narrow wall mount, mounting kit included 

2201011001CA 

Hard Mount Holder flat 

2x Holder for flat wall mount, mounting kit included 

2201012001CA 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 3041110002CA

Page 1: ... Heat Dissipation Real time I V programming Real time I V monitoring Reference voltage f autonomous programming CSB Current Share Bus Inhibit for safe interlocking Remote Shutdown Sense mode Power Good Relay DC ok Precise dynamics on load change Series parallel operation up to 100kW EMC conducted class B radiated class A Efficiency 92 94 PFC Powerfactor 0 99 Variable controlled fans from Papst Lon...

Page 2: ...ghest standards of safety and interference suppression The device was developed in accordance with the requirements of EN61010 1 EN61010 2 201 EN62368 1 and the EMC standards EN55032 conducted Class B radiated Class A The mechanical design of the CPS EX2000 device series is unique It is the first power supply line in the world market which can be flexibly adapted to any installation situation The ...

Page 3: ...ect load The lock can be controlled remotely or repeal by disconnection from the mains again Continuous Mode The unit can be operated in continuous mode In the continuous mode the power supply provides constant current mode in a continuous flow and no ticker operation Master Slave Mode Ureg OUT Ireg OUT The master slave mode can be defined in the parallel operation One device can be set as the mas...

Page 4: ...over all Accuracy Ureg 0 5 Ireg 1 Umon 0 5 Imon 1 Uref 1 Temperature Control yes thermal shutdown autorecovery 70 C outside measuring point distance 10mm Hold Up Time 30ms 230Vac mains buffering at full load Inrush Current 14 6Aeff 20 7Apeak 230Vac active electronic inrush protection no simple NTC Startup Delay typ 1s Softstart typ 100ms Ambient Temperature 20 C 60 C operating derating 2 5 C 50 C ...

Page 5: ...ailure Open Collector 8 INH Output Signal Inhibit Active Open Collector 9 OT Output Signal Over Temperature Open Collector 10 TA Output Signal Temperature Alarm Open Collector Early warning 11 OCP Output Signal Over Current Protection Open Collector 12 CC Output Signal Constant Current Mode Open Collector 13 OVP Output Signal Over Voltage Open Collector 14 CV Output Signal Constant Voltage Mode Op...

Page 6: ...7 01 3 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death Schematic of the internal circuits CON1 4 NC NC ...

Page 7: ...60 C 250Vac 20A Neutrik PowerCon 3x2 5 mm Neutrik NAC3FCA Copy of the original instruction http www neutrik com de powercon powercon 20 a nac3fca Interface pluggable Push Pull Connectors from Weidmueller included Input Power Connector Neutrik NAC3FCA included Output Power Connection M8 Powerbars Lock Pins snap into the 2U 3U 19 subrack WARNING OUTPUT CONNECTION INSTRUCTION Mount the cable lugs dir...

Page 8: ...usted analog control signal The monitor signal is analog linear to the output voltage The monitor signal for current and voltage is the real value that is measured directly at the output of the power supply If a sense line is connected to compensate for the voltage drop across the load lines the monitor signal is exactly the value that is measured at the connection point of the sense line The desc...

Page 9: ...y To avoid interference twist the sense lines To reduce inductive effects we recommend that the load lines position is close to each other To supply a pulsating load the use of an electrolytic capacitor and a cermic capacitor has proved The internal Over Voltage Protection OVP of the power supply controls the DC power directly to the DC output terminals In case of an error the OVP acts automatical...

Page 10: ... message An uneven load and thus premature aging of the participating devices is prevented Connect CON3 contact 5 CS to contact 13 of the slave Are other devices involved in the parallel operation you may grind the CS bus through from unit to unit The current division between the devices will be performed automatically The accuracy of the current distribution is 5 at Iout 0 5 x Iout max Derate the...

Page 11: ...uxiliary Voltage 12V AUX The power supply offers an auxiliary voltage 12V 500mA The accuracy is 500mV Ripple Noise 30mVpp The auxiliary voltage is not affected by the control signals Standby SB Shutdown SD and Inhibit INH and remains always active Between auxiliary voltage and the power output is a reinforced Isolation of max 400Vdc and a basic isolation of max 600Vdc working voltage DC OK Relay D...

Page 12: ...en Collector IMAX 10mA VLOW 0 6V VMAX 30V When OVP INH SB SD FF OCP OT or defective PFC occur the mes sage signal CC is low because the power output is switched off The change between the CV and the CC mode is automatic Please pay attention to the DIP switch setting of the Fuse Mode to avoid provoking malfunction CC Mode Over Current Protection in the Fuse Mode OCP The alarm signal OCP is high whe...

Page 13: ...r proportional to the control signal Ureg The desired control signal is selected via the DIP switcher 0 5V 0 10V 0 20mA oder 4 20mA Model Value UA1 V Value IA1 A Value UA2 V Value IA2 A Pmax IA1 IA2 CPS EX2000 024 30Vdc 66 7A 24Vdc 84A 2001 2016W CPS EX2000 036 45Vdc 44 4A 36Vdc 56A 1998 2016W CPS EX2000 048 58Vdc 34 5A 48Vdc 42A 2001 2016W CPS EX2000 072 90Vdc 22 2A 72Vdc 28A 1998 2016W CPS EX200...

Page 14: ...internal components used only the models with an output voltage of 48Vdc and later are approved for series operation Other power supplies are not approved for series operation above 60Vdc If the units are remotely controlled via the analog interface it is compulsory to use a potential free control voltage Parallel Operation N 1 Decoupling To increase the overall power of the power supply up to 5 u...

Page 15: ...l Germany P 15 21 07 2017 01 3 Tel 49 721 46596 0 Fax 49 721 46596 77 www camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death ...

Page 16: ...ting damage can happen to the power supply unit For the field test owner follow the below instruction a Use suitable test equipment raising the voltage slowly b Short circuit L1 and N and all the DC output terminals c Use only test voltages of 50 60Hz The outputs are unearthed and therefore they have no resistance to GND PE d If the residual voltage is 60Vdc observe the safety standards Use only s...

Page 17: ...result in injury or death Mechanics Aluminium housing IP20 Cooling is achieved via front to rear fans To ensure adequate heat dissipation 50mm to the front and 150mm blockade free distance from the device back wall must be guaranteed The harnesses are to be designed and installed to that the air outlet of the unit is not being blocked In a rack mounting of multiple subracks the rear distance of th...

Page 18: ...ww camtec gmbh com info camtec gmbh com Subject to alterations This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death 19 Subrack 2U 3U 2U Subrack for 1 3 CPS EX2000 with up to 6kW continuous power 3U Subrack for 1 5 CPS EX2000 with up to 10kW continuous power ...

Page 19: ...to custom design power supplies Steplessly hard mount of the CPS EX2000 3000 power supply modules in a 3D room In practice that means that one can mount the modules into every angle imaginable Our 3D Heat Dissipation 3D HD ensures optimal cooling in each mounting position you may consider All you may consider is to make sure that at least a distance of 5cm 2 Inch to the front cooling slots and 15c...

Page 20: ...on Article Number CPS EX2000 024 R2 24Vdc model incl analogue interface 3041110002CA CPS EX2000 036 R2 36Vdc model incl analogue interface 3041110003CA CPS EX2000 048 R2 48Vdc model incl analogue interface 3041110004CA CPS EX2000 072 R2 72Vdc model incl analogue interface 3041110005CA CPS EX2000 110 R2 110Vdc model incl analogue interface 3041110006CA Certifcate Calibration Separate works certific...

Page 21: ...bolts or operation outside the specified herein specification or in an unsuitable environment has the immediate loss of warranty to follow We disclaim any responsibility for any resulting damage to persons or things 4 Note The device must not be operated without an upstream circuit breaker CB We recommend the use of B Type 16A It is prohibited to use the unit without PE It may be necessary upstrea...

Reviews: