Note! Any remote changes in the radio link settings after mounting the units on
the poles should begin at the transmitter side. Otherwise, changing the operation
channel in the receiver unit, for instance, may result in breaking the connection
with the transmitter units and, therefore, it might render their remote r
e-configu
-
ration impossible.
Plug the power cord with a standard
RJ45
connector tip to
WAN PoE 24V
in
CDS-6IP-
eco
module (A), the other end is connected to the connector labeled
POE
in the
supplied PoE power supply (B). To the second connector in
CDS-6IPeco
module (A),
marked as
LAN PoE 24V
connect the cable network the computer or IP camera (C).
8
EU
EU
POLISH
MARK
POLISH
MARK
CDS-6IPECO User’s manual
5. Connection to the system.
Option 1
(Power CDS-6IPeco module by PoE, connect the camera to the module)
Scheme 2. Option 1 devices connection
Scheme 3. Option 2 devices connection
Follow all the steps in
Option 1
. In addition to the LAN connector on the PoE power
supply
(B)
connect the second camera
(D)
.
Option 2
(Extension of Option 1 for a second camera)
!
Power socket
LAN
LAN+PoE24V
POE
LAN
A
B
C
Power socket
LAN
LAN+PoE24V
LAN
POE
LAN
A
D
B
C
CAMERA
CAMERA
CAMERA