Note! Any remote changes in the radio link settings after mounting the units on
the poles should begin at the transmitter side. Otherwise, changing the operation
channel in the receiver unit, for instance, may result in breaking the connection
with the transmitter units and, therefore, it might render their remote re-configu-
ration impossible.
Insert the plug of the standard cable with the RJ45 termination into the LAN
connector in the CDS-5IPmini module. Connect the other termination to
the connector marked as
“Data & Power Out”
in the PoE unit delivered together with
whole set. Connect the computer / IP camera / recorder with the network cable to
the second connector in the power supply unit, marked as
“Data In”
.
Plug the power cord with the RJ45tip to LAN connector in CDS-5IPmini module and the
other end into the
"POE"
connector splitter. Connect computer / IP camera / recorder
to
"LAN"
connector in the manifold by network cable.
Then, connect the cable from the power supply to the camera and splitter.
To configure any CDS-5IPmini module, follow the proper sequence, beginning at the
receiver point. Configure the module in the workshop environment, without prior hang
-
ing it on the structure. Before setting the radio system, configure the IP camera. Install
it on the computer and check whether the video is being received correctly.
a)
Check the addresses of the IP cameras and the address of the CDS-5IPmini
module. Set the computer IP address so that all the devices work within one
subnet (recommended IP addresses: 192.168.1.0-192.168.1.254). It is not
acceptable to set two identical addresses within one local network.
8
EU
EU
POLISH
MARK
POLISH
MARK
CDS-5IP
MINI
User Guide
5. Connection to the system.
Option 2
Option 1
6. First system start-up
!
LAN/PoE
Power Socket
Reset Ground
Data In
Data &
Power Out
mini
LAN/PoE
POE
12V DC
LAN
Reset Ground
mini
Summary of Contents for CDS-5IPmini
Page 23: ......