Check the burner flames through visible flame window to make sure the
combustion is normal during operation of the water heater.
1) Burner with pure blue flame, means well ventilation and combustion adequacy.
2) Burner with yellow/red flame, means combustion insufficiency, air intake is not
enough, or appliance bottom block.
3) Burner with a lift-flame, over gas pressure, high wind condition.
4) Max gas but small flame, gas pressure is not enough.
All piping should be checked for gas and/or water leaks. Refer to page 4 of this
manual for instructions on leak testing.
The air intake and cold water supply filters should be cleaned monthly. For clean
panel surface, dust off and use kitchen cleaner to clean when you feel it is dirty.
DO NOT operate the water heater if you feel something is wrong with the unit.
DO NOT allow children to operate or otherwise handle the unit.
DANGER: Before disconnecting the water supply, make certain no one
will be exposed to the danger of the hot water released by disconnecting.
The water may be hot enough to create a scald hazard. The water should be
released into a suitable drain to prevent injury or property damage.
DANGER: Hotter water increases the potential for hot water scalds.
DANGER: Failure to perform the recommended routine preventative
maintenance can harm the proper operation of this water heater, which can
cause carbon monoxide dangers, excessive hot water temperatures and
other potentially hazardous conditions.