10. Gently pull out the Optical Fiber jumpers.
Take the one that is
ALL YELLOW
and remove the protective cover off the end and
quickly plug it into the BMCC’s
LEFT
side of the dual-LC Optical port.
Use extreme caution and attention as to NOT touch the end of the now unprotected
fiber to anything as this can cause contamination and render the connection faulty.
Take the fiber that has the
WHITE END
and remove the protective cover off the end and
quickly plug it into
RIGHT
side of the BMCC’s optical port.
Use extreme caution and attention as to NOT touch the end of the now unprotected
fiber to anything as this can cause contamination and render the connection faulty.
Detail of both fibers connected to the BMCC is below.
11. Next carefully bring the top over the bottom. Set the fiber jumpers into the cavity provided
under the Neutrik OpticalCON connector housing. Guide the fiber connection on the BMCC into
the two small rectangular cut-outs in the bottom for alignment and good fit as shown below.