8.5.2 034B Met One Windset
Mount the 034B to the CM202, CM204, or CM206 crossarm as shown in
FIGURE
1.
Mount the CM220 bracket on the crossarm via the U-bolt and nuts.
2.
Place the 034B stem and bushing into the CM220 bracket.
3.
With the shoulder screw in place, orient the counter weight to point due
south. See Section
Wind Direction Sensor Orientation
(p. 50)
, for
final calibration.
4.
Tighten the CM220’s U-bolt and nuts and remove the shoulder screw.
FIGURE 8-16. Met One 034B Wind Speed and Direction Sensor
8.5.3 05103, 05103-45, 05106, and 05305 RM Young Wind Monitors
Mount the Wind Monitor to the CM202, CM204, or CM206 crossarm as
shown in FIGURE
1.
Attach the CM220 bracket on the crossarm via the U-bolt and nuts.
2.
Position the top of the mounting post 5 in above the CM220 and tighten
the set screws.
3.
Slide the orientation ring and the Wind Monitor onto the mounting post.
Rotate the sensor base so that the square wiring box points south. Engage
the key in the orientation ring with the keyway on the sensor and tighten
the band clamps (see Section
Wind Direction Sensor Orientation
(p. 50)
, for final calibration).
4.
Remove the plastic nut on the propeller shaft. Slide the propeller onto the
shaft (face the side with the lettering out) and replace the nut.
Summary of Contents for UT10
Page 2: ......
Page 6: ......
Page 35: ...UT10 Universal Tower 25 FIGURE 8 9 SRM 5A Rad Modem and SC932A Interface ...
Page 36: ...UT10 Universal Tower 26 FIGURE 8 10 SRM 5A wiring Computer Datalogger ...
Page 50: ...UT10 Universal Tower 40 FIGURE 8 21 HMP60 Temperature and RH Probe HMP60 Mounting Clamp ...
Page 68: ...UT10 Universal Tower 58 ...
Page 69: ......