UT10 Universal Tower
29
8.3.5.3 Install Nearest Repeater/Field Station
Now install the nearest field station. If it communicates with the base station
via a repeater, the repeater station must also be installed. Make sure the correct
RF ID has been configured in the RF500M that is being deployed in the remote
field station or repeater location.
The following is the order in which a general RF field station should be
installed. A repeater station is installed in the same order.
1.
Tripod or tower
2.
Enclosure and datalogger
3.
Antenna - Orient correctly; remember direction and polarization
4.
Solar panel
5.
Power supply
6.
Sensors
7.
RF modem - Configure the RF ID according to the site map
8.
Radio - Make sure to connect to RF Modem, to power supply, and turn on
power supply
8.3.6 MD485 Multidrop Interface
Campbell Scientific’s MD485 is an intelligent RS-485 interface that permits a
PC to address and communicate with one or more dataloggers over a distance
of 4000 ft. The distance between the datalogger and computer can be increased
by combining it with a phone modem, Ethernet link, or spread spectrum radio.
8.3.6.1 MD485 Multidrop Interface at the Datalogger
1. Mount the MD485 to the enclosure backplate via its onboard bracket.
2. Attach the SC12 cable’s female connector to the MD485’s
CS I/O
port.
3. Attach the SC12’s male connector to the datalogger’s
CS I/O
port.
4. Attach a twisted pair cable such as the CABLE2TP to one of the MD485’s
RS-485
ports.
8.3.6.2 MD485 Multidrop Interface at the Computer
1. Connect the CABLE2TP cable to one of the MD485’s
RS-485
ports.
2. Attach one end of pn 10873 RS-232 cable to the MD485’s
RS-232
port.
3. Attach the other end of pn 10873 RS-232 cable to the computer’s
RS-232
port.
4. Attach the barrel plug of pn 15966 wall charger to the MD485’s Pwr port,
then plug the wall charger into an AC outlet.
Summary of Contents for UT10
Page 2: ......
Page 6: ......
Page 35: ...UT10 Universal Tower 25 FIGURE 8 9 SRM 5A Rad Modem and SC932A Interface ...
Page 36: ...UT10 Universal Tower 26 FIGURE 8 10 SRM 5A wiring Computer Datalogger ...
Page 50: ...UT10 Universal Tower 40 FIGURE 8 21 HMP60 Temperature and RH Probe HMP60 Mounting Clamp ...
Page 68: ...UT10 Universal Tower 58 ...
Page 69: ......