Appendix F. Data Dump Datalogger Program
F-2
After waiting twenty seconds, set the scan rate to 0 and check the buffer with
*#60 commands 7 and 5. If a number other than 0000 is displayed, the steps
for setting user FLAG 2 HIGH must be repeated.
F.6 CR10X Data Dump Program
;
*Table 1 Program
01: 10.0
Execution Interval (seconds)
01: If Flag/Port (P91)
1:
11
Do if Flag 1 is High
2:
30
Then Do
02: Do (P86)
1:
10
Set Output Flag High
03: Sample (P70)
1:
20
Reps
2:
1
Loc [ Data ]
;Transfer "test" data of 20 zeros (60 bytes) to Random buffer for test transmission
04: Data Transfer to GOES (P120)
1:
11
random buffer/overwrite the old data
2:
1
FWD/Ref Power Loc [ Data ]
05: Do (P86)
1:
21
Set Flag 1 Low
06: End (P95)
07: If Flag/Port (P91)
1:
12
Do if Flag 2 is High
2:
30
Then Do
;Clear Random buffer to prevent random transmissions.
08: Data Transfer to GOES (P120)
1:
11
random buffer/overwrite the old data
2:
1
FWD/Ref Power Loc [ Data ]
09: Do (P86)
1:
22
Set Flag 2 Low
10: End (P95)
F.7 21X Data Dump Program
The 21X's program is the same as the CR10X and CR10's, except Instruction
99 has an extra parameter. With this parameter, you specify the array of data
that is transferred to the buffer (see Section 9.2).
Summary of Contents for TGT1
Page 2: ...This is a blank page ...
Page 4: ...This is a blank page ...
Page 6: ...This is a blank page ...
Page 10: ...TGT1 GOES Transmitter Table of Contents iv This is a blank page ...
Page 36: ...TGT1 GOES Transmitter 26 This is a blank page ...
Page 38: ...This is a blank page ...
Page 40: ...This is a blank page ...
Page 42: ...This is a blank page ...
Page 54: ...Appendix G Local Magnetic Declination G 4 This is a blank page ...
Page 58: ...Appendix H Changing the CR10 s RAM or PROM Chips H 4 This is a blank page ...
Page 61: ...J 1 Appendix J Telonics Model TGT1 Certification by NOAA NESDIS ...
Page 62: ...This is a blank page ...