Section 3. Sensor Alignment and Installation
3”
S
URFACE
PREP
.
LOCATIONS
FIGURE 3-2. Surface Preparation - Location
3.2 Installation
Once surface preparation is complete, the transducer can be installed using the
selected mounting technique (see
Sections 5- Mounting of Sensors to Various
Surfaces
). The two marks 1.5 inches from the center-line are used to locate the
transducer longitudinally; align these marks with the center of the transducer
feet. Notice that the front of the transducer (end opposite of the cable) as been
machined to a slight point. This point, along with the cable exit on the rear of
the transducer, should be aligned with the measurement axis line to ensure that
strain is being measured parallel to the measurement axis. An installed
transducer can be seen in the picture below. Note that if an R/C extension is
used, the longitudinal mark will need to be 30 inches long in order to be seen
behind the transducer/ extension combination. It is important that this line is
drawn carefully as the strains are inherently more susceptible to error due to
misalignment as the gage length increases.
FIGURE 3-3. ST350 Mounting Example
3-2
Summary of Contents for ST350
Page 6: ...Section 1 Introduction 1 2...
Page 8: ...Section 2 Specifications 2 2...
Page 12: ...Section 3 Sensor Alignment and Installation 3 4...
Page 22: ...Section 5 Mounting of Sensor to Various Surfaces 5 8...
Page 24: ...Section 6 Calibration and Validation 6 2...
Page 28: ...Section 7 Maintenance Replacement Parts and Repairs 7 4...
Page 32: ...Section 8 Datalogger Programming 8 4...
Page 44: ...Appendix B ST350 Accuracy Verification B 6...
Page 49: ...This is a blank page...