Appendix F. SR50ATH Heater Operation
F-3
2. Separate the housing from the sensor body and disconnect the connector
from the transducer to the main sensor body.
3. To replace the desiccant, remove the desiccant holder plate with the
Phillips 4-40 screw. Cutting the tie strap will allow the old packets to be
removed for replacement. During reassembly, ensure that the desiccant
does not come in contact with the metal backing of the transducer. If only
the desiccant is being inspected or replaced, steps 4 and 5 are not required.
Steps 4 to 6 are required to replace the transducer only.
4. Your transducer kit comes with a replacement for the O-ring that seats
between the main sensor body and the plastic transducer housing. Ensure
that the new O-ring is used when reassembled.