Appendix D. RS-232 and RS-485 Operation
D-2
TABLE D-1. SR50AT RS-232 Interface Wiring
SR50AT
Wire Colo
u
r
Function
Wiring Location
Red
+12 Vdc Power
Power Source (Datalogger:
12V
)
Black
Power Ground
System Ground and/or RS-232
Receiver Ground (Datalogger:
G
)
Green
RS-232
(SR50AT
Output)
Pin 2 [RXD] (9-pin RS-232 Interface
Connector: pn
#
28840)
White
RS-232
(SR50AT Input)
Pin 3 [TXD] (9-pin RS-232 Interface
Connector: pn
#
28840)
Clear
Shield
G
(datalogger)
Jumper Wire
Pin 5 [
G
] (9-pin RS-232 Interface
Connector: pn
#
28840)
TABLE D-2. SR50AT Datalogger COM Port Wiring
SR50AT Wire
Colo
u
r
Function
CR1000
CR6
Red
+12 Vdc Power
12V
12V
Black
Power Ground
G
G
Green
RS-232
(SR50AT Output)
RX (
COM1
–
COM4
)
RX (
COM1
–
COM2
)
White
RS-232
(SR50AT Input)
TX (
COM1
–
COM4
)
TX (
COM1
–
COM2
)
Clear
Shield
G
G
D.2 RS-485 Operation
The SR50AT sensor comes from the factory with the internal jumpers set to
SDI-12 mode. To use the SR50AT in the RS-485 mode of operation, the
jumpers need to be set as outlined in Appendix
(p. C-1)
Complete RS-485 CRBasic programs can be found in Appendix
(p. B-8)
.
The RS-485 on the SR50AT supports half-duplex communications, which
means the SR50AT can receive and transmit data, but not simultaneously.
Normally a master-slave relationship is used in most systems to avoid
collisions between transmissions. For this reason, the
Auto Measure Output
is
not recommended for RS-485 communications. It is much better to have a
master initiate the communications by using the
Measure On Poll
or the
Auto
Measure Polled Output
modes.
You can use Campbell Scientific’s MD485 interface to connect one or more
SR50AT sensors in RS-485 mode to an RS-232 device. This can be useful for